background image

 

 

Contact 

 

Testo Sensor LD basic V1.01 EN 

 

Seite 

22

 von 

22

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Testo Sensor GmbH 

Testo-Strasse 1 
D-79853 Lenzkirch 
 
Mail: 

 [email protected]

 

Web

www.testo-sensor.com

 

 

 
 

Содержание Sensor LD basic

Страница 1: ...EN English Testo Sensor LD basic V1 01 EN Seite 1 von 22 Instruction manual Leak detector Testo Sensor LD basic ...

Страница 2: ...PTION OF THE DIFFERENT SENSOR TYPES 8 10 START UP APPLICATION TESTO SENSOR LD BASIC 9 10 1 SWITCH ON 9 10 2 HEADPHONE VOLUME UP VOLUME DOWN 9 10 3 SENSITIVITY LEVEL 9 10 4 LASER ON OFF 10 11 OPERATION 10 11 1 INITIALIZATION 10 11 2 SCREEN LECKAGE 11 11 3 SETTINGS MENU TESTO SENSOR LD BASIC 12 11 3 1 Language 13 11 3 2 Date Time 13 11 3 3 System settings 14 11 3 3 1 System update 14 11 3 3 2 Reset ...

Страница 3: ...ot and or rotating parts Always switch on the device before putting on the headphones At high signal levels bar graph headphones in the red area the volume can be correspondingly large The sensitivity setting can be used to reduce the volume Observe the prescribed storage and operating temperatures In case of improper handling or violence the warranty claims are lost Interventions on the device of...

Страница 4: ...cumulator is contained in this electrical appliance Battery type Chemical system Akkumulator LiIon 2S1P Information on the safe removal of the batteries or accumulators Warning Make sure that the battery is completely empty Removing the battery Removing the battery cover Disconnecting the connector Carefully pull out the battery Carefully remove the accumulator The accumulator and the appliance ca...

Страница 5: ...me 10 h continuous operation Charging ext battery charger included in scope of delivery Charging time c Max 4h Laser Wavelength 630 660nm output power 1mW laser class 2 Connections 3 5 mm stereo jack for headset Power supply socket for connecting an external charger USB connection Colour screen 3 5 touch panel TFT transmissive Interface USB for SW update Application Area Indoor use Operating tempe...

Страница 6: ... 1 Name plate 7 2 Laser warning label Acccording IEC 60825 1 2014 Max output power 1mW 630 660nm Complies with 21 CFR 1040 10 and 1040 11except for conformance with IEC 60825 1 Ed 3 as described in Laser Notice No 56 dated May 8 2019 Laser 2 7 3 Label position 8900 0402 8900 0402 ...

Страница 7: ... 8 Device components and controls 8 1 The Testo Sensor LD basic 3 5mm jack for the headphone Acoustic trumpet USB Connection Plug in connection for power supply battery charger socket Save button Volume On Off button Foil keypad 4 buttons 3 5 TFT colour display with touch panel ...

Страница 8: ...mpressed air components are then checked for precise detection Quantification distance distance 1 6 m Use of acoustic trumpet Average distance to pipe component 0 2 6 m Low interfering noise Leakage freely accessible The straightening tube permits only very few ultrasonic waves to pass in the direction of the ultrasonic transducer allowing leakages to be located very precisely For this reason the ...

Страница 9: ...dness of the leakage With the Sensitivity button the sensitivity of the Testo Sensor LD basic can be adjusted to the environment which strongly influences the acoustic behaviour of the device and increases or decreases the valid value range A reduction in sensitivity reduces the range of the leakage The sensitivity levels or the automatic function are selected via the Sensitivity button Sensitivit...

Страница 10: ... via the touch panel The selection of the respective menu items occur via short tapping with the finger or a soft round pen Attention Please use no pens or other objects with sharp edges The foil can be damaged 11 1 Initialization After switching on the Testo Sensor LD basic the initialization takes place and then switch to leakage display Laser On Icon Please note the warnings for laser operation...

Страница 11: ... picture shows and describes the display elements Date Time Battery condtion indicator Battery condition 22 Power supply connected and battery is charging Laser On Icon Date Time and battery condition indicator Bar graph of Signal level Sensivity level button Settings menu Signal Level in dB ...

Страница 12: ...apping with the finger or a soft round pen Attention Please use no pens or other objects with sharp edges The foil can be damaged Before the leakage search is started the device must be configured The user can access the menu by clicking the Settings button The following figure shows the Settings Menu Settings With the button Settings you access the basic menu of the Testo Sensor LD basic Return t...

Страница 13: ... Date Time Here you can select one of 13 languages for the Testo Sensor LD basic For languages on page 2 please press By pushing the Time Zone description field and enter the correct UTC you can set the correct time all over the world The summer and wintertime switchover is realized by pushing the Daylight Saving button ...

Страница 14: ...ck USB Stick for new Updates P1 V033 C1 I1 Update Kanäle If it is required to install an older software version you have press the button Force all Overview of System Update Functions f after pressing the button Check USB Stick for new Software updates the following messages appear in the window is the Testo Sensor LD basic is not properly connected to the USB flash drive or there are no files ava...

Страница 15: ...ault settings a safety prompt is displayed and must be confirmed by pressing the button Yes If necessary the touch screen calibration can be changed here Push Calibrate and it appears 1 left above 2 bottom right 3 bottom left 4 right above and 5 in the middle a calibration cross that must be pushed consecutively If the calibration finished positive a message Calibration successful appears and have...

Страница 16: ...anently on in the currently set brightness Here you adjust the desired Backlight 15 100 of the display directly E g Backlight to 39 With the help of the Backlight dimming after button after a definable time interval here after 15 minutes the Backlight can be reduced to the minimum As soon as the dimmed screen is operated again the Backlight is committed automatically on the last set value before d...

Страница 17: ...er of the Testo Sensor LD basic Under options you can buy four additional different functions if you have not done this by ordering This function can be used for cleaning the touch panel during running measurements If one minute is not enough time to clean the process can be repeated at any time Is the cleaning faster finished then you can push the to abort press long button for one or two seconds...

Страница 18: ...cket of the Testo Sensor LD basic and the 230V socket The Testo Sensor LD basic checks the charging status of the battery and starts the charging process automatically if necessary To protect the Li ION accumulator of exhaustive discharge the device is switching off automatically if a cell voltage of 6 4V will be reached Connect external power supply to the charging socket Symbol CHG is displayed ...

Страница 19: ...respective order numbers Description Order number TESTO Sensor LD basic ultrasound detector set consisting of 8900 0401 TESTO Sensor LD basic ultrasound detector basic device 8900 0402 Acoustic trumpet 8800 0303 Soundproof headset 8800 0304 Focus tube with directional tip 8800 0305 Battery charger 8800 0306 Transport case 8800 0307 Focus tube with focus tip 8800 0305 Soundproof Headset 8800 0304 B...

Страница 20: ...Appendix Testo Sensor LD basic V1 01 EN Seite 20 von 22 14 Appendix In the appendix on the following pages you will find the Test Report of the Li ion batteries used 14 1 Report UN 38 1 ...

Страница 21: ...Operation Testo Sensor LD basic V1 00 EN Seite 21 von 22 14 2 Report IEC62133 2 ...

Страница 22: ...Contact Testo Sensor LD basic V1 01 EN Seite 22 von 22 Testo Sensor GmbH Testo Strasse 1 D 79853 Lenzkirch Mail info testo sensor de Web www testo sensor com ...

Отзывы: