![TESTO Saveris 2 H2 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/testo/saveris-2-h2/saveris-2-h2_commissioning-instructions_1092433062.webp)
6
Commissioning
62
truck is at the charging station). The mobile radio data logger must not be
registered on any Saveris router or Saveris converter.
The Saveris extender is used to pass on the collected logger data to the Saveris
base, along with data from the Saveris base to the Saveris cockpit unit.
The Saveris extender is designed for both mobile and stationary data
monitoring. In comparison to the Saveris converter, the main difference
is that the transmission paths of the components involved are not
strictly defined in the case of the Saveris extender. The radio data
loggers registered on the base each search for the best radio link and
then communicate via the appropriate Saveris extender. This is a major
advantage when the radio quality may change in terms of time or
spatial conditions, e.g. in a warehouse.
In principle it is preferable to use the Saveris extender rather than the
Saveris converter.
Please note that when using a stationary Saveris extender it is not
possible to trace the transmission/communication path of the
measurement data in the
System
software menu, because there is no
1 to 1 connection between the Saveris extender and the radio data
loggers or routers.
The measurement data of up to 100 radio probes can be transmitted to
the Saveris base using a Saveris extender. At least two cycles (30 min)
are recommended for reliable data transfer as a minimum retention time
for the mobile unit on the ramp.
As the mobile radio data loggers only have a limited internal memory, it
is necessary to ensure that they come into radio contact with a Saveris
extender on a regular basis, depending on the measuring cycle, in
order to enable the measurement data to be transferred.
You can connect several Saveris extenders to the Saveris base via a
switch. In this connection, note that up to 20 Saveris extenders can be
registered on the Saveris base with a maximum number of 150 radio
data loggers or 450 measurement channels. If the connection is to be
made via VPN, please contact our support team.
The procedure for preparing the commissioning of a Saveris extender is
the same as with an Ethernet data logger, see section 6.9.2
Integrating
testo Saveris Ethernet data logger (optional)
.
6.9.8
Integrating Saveris cockpit unit (optional)
The Saveris cockpit unit is used to start and stop tours manually and to display
the readings of the assigned Saveris radio data loggers during transport. The
driver is alerted about any violations of limit values by a red LED. In addition, the
2
Component is only permitted for mobile monitoring in all countries with a radio
frequency of 868 MHz.
Содержание Saveris 2 H2
Страница 2: ......
Страница 44: ...6 Commissioning 44 5 6 5 7 8...
Страница 117: ......
Страница 118: ......
Страница 119: ......