background image

 

Table of contents 

Testboy

® 

TV 441

 

15 

EN

G

LI

SH

 

E

N

GLI

S

H

 

Table of contents 

Information 

16

 

Safety information 

16

 

General safety notes 

16

 

Safety 

19

 

Description 

20

 

Description of the test instrument 

20

 

LC-Display 

21

 

Specifications 

21

 

Range specifications 

21

 

Test procedure 

22

 

Operation 

22

 

Measuring the earth voltage 

22

 

Two pole-measurement of the earth resistance 

22

 

Three pole-measurement of the earth resistance 

23

 

Saving data 

24

 

Reading out data 

24

 

REL 

– Relative measurement 

24

 

MAX/MIN/AVG measurement 

24

 

Deleting data 

25

 

Backlighting 

25

 

Automatic deactivation 

25

 

Replacing the battery 

25

 

Technical data 

26

 

 

Содержание TV 441

Страница 1: ...Testboy TV 441 Version 1 0...

Страница 2: ...Testboy TV 441 Bedienungsanleitung 3 Testboy TV 441 Operating instructions 15...

Страница 3: ...splay 9 Spezifikationen 9 Bereichsspezifikationen 9 Messverfahren 10 Bedienung 10 Messung der Erdspannung 10 Zweipolige Messung des Erdwiderstandes 10 Dreipolige Messung des Erdwiderstandes 11 Datensp...

Страница 4: ...tshinweise Warnvermerke und das Kapitel Bestimmungsgem e Verwendung unbedingt beachten WARNUNG Beachten Sie vor dem Gebrauch des Ger tes bitte folgende Hinweise Vermeiden Sie einen Betrieb des Ger tes...

Страница 5: ...leitung verursacht werden erlischt der Garan tieanspruch F r Folgesch den die daraus resultieren bernehmen wir keine Haftung Testboy haftet nicht f r Sch den die aus dem Nichtbeachten der Anleitung vo...

Страница 6: ...n auftreten gew hren wir eine Garantie von 5 Jahren nur g ltig mit Rechnung Fabrikations oder Materialfehler werden von uns kostenlos beseitigt sofern das Ger t ohne Fremdeinwirkung und unge ffnet an...

Страница 7: ...itzen nie mit nassen H nden anschlie en oder wenn die Oberfl che des Messger tes feucht ist W hrend einer Messung nicht die Messleitungen oder Pr fspitzen ber hren Nicht das Batteriefach ffnen wenn da...

Страница 8: ...ehwahlschalter Umschalten zwischen Messung der Erdspannung und zweipoliger oder dreipoliger Messung des Erdwiderstandes 2 Taste APS Aktiviert oder deaktiviert die automatische Abschaltfunktion 3 Taste...

Страница 9: ...cher 2POLE Zweipolige Widerstandsmessung 3POLE Dreipolige Widerstandsmessung V Volt Spannung K Ohm Widerstand Bei aktivem Symbol ist das automatische Abschalten aktiviert Bei aktivem Symbol ist der Ba...

Страница 10: ...den siehe Kapitel Batteriewechsel Messung der Erdspannung Den Drehwahlschalter auf VE drehen Die Messleitungen an die Buchsen E und S anschlie en und die anderen Enden der Messleitungen mit der Spannu...

Страница 11: ...Das Messger t verwendet f r die Messung des Erdwiderstandes das Spannungsabfallverfahren Der Erdwider stand RX wird ermittelt indem zun chst der Nennstrom I zwischen dem Messobjekt E den Staberdern un...

Страница 12: ...ten gespeichert waren werden diese berschrieben Auslesen von Daten Durch Auslesen der Daten lassen sich die im Messger t gespeicherten fr heren Messungen berpr fen 1 Im Standby MEMO dr cken um die Anz...

Страница 13: ...matischer Abschaltfunktion ert nt nach 15 Mi nuten Inaktivit t ein Signal und das Messger t wird in den Ruhezustand geschaltet Das Ger t kann durch Dr cken einer beliebigen Taste wieder aktiviert werd...

Страница 14: ...0 4000 Erdspannung 0 200 V 50 60 Hz Lagertemperatur 10 C bis 50 C RH 85 Betriebstemperatur 0 C bis 40 C RH 85 Spannungsversorgung 6 x 1 5 V Typ AA Mignon Gewicht 3 45 kg Abmessungen 330 x 125 x 265 Zu...

Страница 15: ...21 Specifications 21 Range specifications 21 Test procedure 22 Operation 22 Measuring the earth voltage 22 Two pole measurement of the earth resistance 22 Three pole measurement of the earth resistanc...

Страница 16: ...he section Intended use WARNING Comply with the following specifications before using the instrument Do not operate the instrument anywhere near electric welders induction heaters or other electromagn...

Страница 17: ...instructions We assume no liability for any resulting damage Testboy is not responsible for damage resulting from Failure to comply with the instructions Changes to the product that have not been app...

Страница 18: ...y valid only with invoice We will repair production or material defects free of charge upon return provided that the instrument has not been tampered with and is returned to us unopened Damage resulti...

Страница 19: ...ads or test rods with wet hands or if the surface of the measuring instrument is damp Never touch the test leads or test rods during measurement Do not open the battery compartment whilst the measurin...

Страница 20: ...rument 1 Rotary switch Switch between measurement of the earth voltage and two pole or three pole measurement of the earth resistance 2 APS button Activates or deactivates the automatic deactivation f...

Страница 21: ...tance measurement 3POLE Three pole resistance measurement V Volt voltage K Ohm resistance With active symbol automatic deactivation is activated With active symbol the battery level is low Identificat...

Страница 22: ...ee chapter Changing the batteries Measuring the earth voltage Turn the rotary switch to VE Connect the test leads to the jacks E and S and connect the other ends of the test leads with the voltage sup...

Страница 23: ...e voltage drop procedure for measurement The earth resistance RX is determined by allowing the nominal current I to flow between the measurement object E the earthing rods and the current pole C and t...

Страница 24: ...up Any data already saved on the selected memory will be overwritten Reading out data Reading out data enables you to check of the earlier measurements saved in the measuring instrument 1 Working in s...

Страница 25: ...will sound after 15 minutes of inactivity and the measuring instrument is switched into resting state The device can be reactivated by pressing any button The rotary switch must be set to OFF if the...

Страница 26: ...tance 0 4000 Earth voltage 0 200 V 50 60 Hz Storage temperature 10 C to 50 C RH 85 Operating temperature 0 C to 40 C RH 85 Voltage supply 6 x 1 5 V Type AA Mignon Weight 3 45 kg Dimensions 330 x 125 x...

Страница 27: ......

Страница 28: ...Testboy GmbH Tel 0049 0 4441 89112 10 Elektrotechnische Spezialfabrik Fax 0049 0 4441 84536 Beim Alten Flugplatz 3 D 49377 Vechta www testboy de Germany info testboy de...

Отзывы: