background image

14

13

General Specifications

Electric

Characteristic

Image

PTZ

operation test

UTP Cable

Test

Size

Input Voltage

Battery

Built-in Charger

TV Type

Image level

Protocol

Transmission

speed

Transmission

mode

Kinds of test 

12V 

±

10%,  above 1A

Chargeable Ni-MH battery 6EA (AA size)

NTSC/PAL

1 Vpp, 140 IRE

Multi-Protocol support

2400bps ~ 38400bps

RS-422,RS-485

direct/cross cable, and broken or short-circuit

can be tested

Charging Time

Operation time

Above 8 hrs

More than 4 hrs

W(88mm) X L(190mm) X T(58mm max)

Meter Specifications

DC Voltage

AC Voltage

DC Current

400mV

4V

4V

400V

4V

40V

400V

100uV

1mV

10mV

100mV

1mV

10mV

100mV

0.2uA

2uA

20uA

200uA

2mA

±

(0.8% + 2dgts)

±

(1.0% + 2dgts)

±

(1.2% + 3dgts)

(40H

~ 500H

z

)

±

(1.0% + 2dgts)

±

(1.5% + 2dgts)

±

(2.0% + 3dgts)

Measuring      Measured Value Minimum                       Accuracy

Item                                          Measuring

4mV

400mV

10A

400uA

4mA

40mA

400mA

10A

Содержание Rapport 337

Страница 1: ...99 Washington Street Melrose MA 02176 Fax 781 665 0780 TestEquipmentDepot com...

Страница 2: ...s of RAPPORT337 6 Standard Items 7 Names Functions of Each Part 8 3 Specifications of Rapport337 13 General Specifications 13 Meter Specifications 14 4 Functional Use 16 Power ON OFF 16 OSD Setup Scre...

Страница 3: ...al is for users of Rapport337 Starting with the outline of Rapport337 the manual is emphasized on the explanations of its operation how to be connected to the other devices how to use every button and...

Страница 4: ...humidity or leaking gas environments Do not touch it with wet hands Be mindful not to shock or shake the unit while in use to avoid damage Avoid the places of strong magnetism or electric wave which w...

Страница 5: ...Analyzer It determins which protocol to control your PTZ Camera from PTZ Controller or DVR This will guide CCTV installer to understand the Protocol and find the fault device easily UPT Cable tester...

Страница 6: ...hecklist below placing them on a level place Rapport337 Main Body User s Manual Test Lead Set Red Black Adapter Rechargeable AA Size Nickel Hydrogen Ni MH Battery 6EA Necklace UTP test Terminal BNC Vi...

Страница 7: ...being charged Red LED is on when data is transmitted Red LED is on when data is received TFT LCD Part Name Function Key Button METER PART Test Lead Connection Test Lead Positioning for Lead Connectio...

Страница 8: ...ly generated Video Test Signals It is the port of input output of communication signal Rx Rx Tx Tx It braces Rapport337 It hangs on the neck for safety It hangs on the neck for safety Part Name UTP Ja...

Страница 9: ...ocol support 2400bps 38400bps RS 422 RS 485 direct cross cable and broken or short circuit can be tested Charging Time Operation time Above 8 hrs More than 4 hrs W 88mm X L 190mm X T 58mm max Meter Sp...

Страница 10: ...with a beep Release the button The power goes off A rechargeable battery should be plugged in over 8 hrs for full charge The charged battery can operate for 4 hrs or so When the battery indicator sho...

Страница 11: ...right left for PTZ is made and zooming manual focus are adjusted UTP Cable Tester mode UTP cable direct cross cable disconnection and short circuit are tested 17 View Information mode At this mode the...

Страница 12: ...when key is pressed And it returns to the initial setup value when one of the two keys is pressed for more than 3 sec C Indicates screen sharpness and the brightness increases gradually by 1 when key...

Страница 13: ...rent below 4mA This button is used to test current below 400mA This button is used to test current below 10A 21 Description of METER MODE LCD WINDOW Part Function Kinds of test to set up Test value to...

Страница 14: ...to beep at below 80 How to measure Connect the red lead to and the black lead to as shown in the figure above at left and measure the resistance directly at the resistance measuring mode by pressing...

Страница 15: ...int and the black lead on point each on the voltage source MEASURING AC DC CURRENT Current is simply defined as a flow of electrons running through a conductor To measure current you must break the ci...

Страница 16: ...ected there may occur burnout of fuses damage or breakdown of the system when the voltage is measured 27 PTZ CONTROLLER How to connect each terminal and LCD screen PTZ Operation Test The basic operati...

Страница 17: ...ized location 29 The controlling code of protocol from the key board or DVR is displayed on the screen Most important however is that the communications speed should be of one accord SPST It memorizes...

Страница 18: ...Setup of PTZ PROTOCOL The initial setup is made PELCO D and changing to PELCO D PELCO P and WONWOO are available in accordance with the protocol mode of PTZ It is done by pressing keys 31 BAUDRATE Se...

Страница 19: ...NFORMATION Mode Setup First press key more than 3 sec and select VIEW INFORMATION on MODE SELECT MENU then press key MAIN SETTING Mode Setup First press key more than 3 sec and select MAIN SETTING on...