COMMISSIONING PROCEDURE
The commissioning process for Wall Connector enables easy configuration of circuit breaker size, Wi-Fi
connectivity, and power sharing options.
Wall Connectors must be commissioned before first use.
1. Turn on Wall Connector's corresponding circuit breaker to energize the unit.
2. Use a Wi-Fi-enabled device such as a smart phone to connect to the SSID Wi-Fi signal broadcasted by
the Wall Connector. Joining the Wall Connector network can be done by scanning the sticker QR code
on the Quickstart Guide cover page, or by manually selecting the network and typing in the WPA2
password (found on the sticker on the Quickstart Guide cover page).
NOTE:
SSID will broadcast for 15 minutes.
NOTE:
If you are unable to connect to the Wall Connector SSID, turn off the cellular data function on
your mobile device and try again.
NOTE:
If the Wall Connector has not been commissioned, a solid yellow light will display on the front
of the main unit to indicate that it is ready to be commissioned.
3. Scan the QR code below with the device that is connected to the Wall Connector to access the web
browser commissioning interface. Alternatively, manually type the URL address (http://192.168.92.1)
into the web browser.
4. Follow the onscreen commissioning steps on the web browser.
NOTE:
To have the Wall Connector broadcast the SSID again, hold the button on the charge handle for
5 seconds or turn the circuit breaker off, then on again.
28
Gen 3 Wall Connector Manual
Содержание Gen 3
Страница 1: ...Gen 3 Wall Connector Manual Type 2 Handle Three Phase ...
Страница 35: ...Revision 1 0 ...
Страница 37: ... O O ...
Страница 38: ......
Страница 39: ...NOTE NOTE ...
Страница 40: ......
Страница 41: ...Figure 3 Charging equipment separated from the TN C S PME supply earth by an isolating transformer ...
Страница 42: ...Figure 4 Charger converted to TT ...