27
7 sPeCiFiCAtions
Temperature range:
Operation at +10 to +40°C storage at -10 to +60°C
Humidity:
30 to 75% (non condensing)
Air pressure:
860 to 1060 hPa
Protection class:
IP20
7.1 Environmental conditions
7.2 Technical capabilities
General
PA 5740
Forward voltage gain
7/1
(switchable)
Bandwidth (-3 dB)
DC to 40 kHz (standard) to 150 kHz (high freq)
Overtemperature shutdown Thermal sensors trip at 80°C (warning) and
90°C (output shut off)
Supply
Supply voltage
1 ph 100/120/230 V ± 10% L, N, PE
Supply frequency
47 to 63 Hz
Supply power
1.4 kVA
Output
Output voltage range
-60 to +60 V
Max continuous output
±10 A
Current
Output impedance
<10 mOhm
Output accuracy
Typical <1%