19
5.1 Compliant with ISO 7637 (and similar) for transient immunity
The PA 5740 is designed to act as the battery source for transient immunity
tests. Most transients must be coupled onto battery voltage and the
NSG 5000
series
with its internal coupling couples the transient and the DC voltage as
required by the standards. Designed with low internal resistance and low noise,
the
PA 5740
is compliant with section 5.4 of ISO 7637-2:2004.
For this application please use compensation mode
CAPACITIVE.
5 APPliCAtions
5.2 Voltage variations for starting profiles
The
PA 5740
series is often used for starting profile simulation (pulse 4 and
variants). In addition, several standards require synchronized starting profiles.
Utilizing the
NSG 5000 series
for control, the
PA 5740
(or the
PA 5840
) is the
best solution for all known starting profiles with up to four synchronized starting
profiles. The
PA 5840
is another automotive battery simulator from Teseq but
for greater power. See the specifications of the
NSG 5000
series for details.
For this application please use compensation mode
CAPACITIVE.
U
A
0