1
PA 5740 - Automotive
bAttery simulAtors
user mAnuAl
601-309A
Advanced Test Equipment Rentals
www.atecorp.com 800-404-ATEC (2832)
®
Established 1981
Страница 1: ...1 PA 5740 Automotive bAttery simulAtors user mAnuAl 601 309A Advanced Test Equipment Rentals www atecorp com 800 404 ATEC 2832 Established 1981...
Страница 2: ...PA 5740 Automotive battery simulators PA 5740 Automotive battery simulators User Manual...
Страница 3: ...sures 10 2 8 Accident prevention regulations 10 2 9 Infringement of safety regulations 10 2 10 Proper use 10 3 Installation Set Up 11 3 1 Checking the shipment 11 3 2 Delivery contents 11 3 2 1 Standa...
Страница 4: ...ging voltage dip applications 20 5 4 Voltage ripple and sine wave noise simulations 20 5 5 Example application with NSG 5500 and NSG 5600 21 6 Maintenance 22 6 1 Cleaning the equipment 22 6 2 Moving a...
Страница 5: ...ies and AutoStar software Designed to meet EMC electromagnetic compatibility immunity testing require ments for the automotive industry Applicable standards include ISO 7637 ISO 16750 JASO D001 MIL ST...
Страница 6: ...rent limit input current limit indicator current and voltage display compensation mode gain setting and output and sense connectors The voltage and current control and monitoring interface is realized...
Страница 7: ...ble to all operating personnel Every operator must be informed exactly where the operating instructions have been stored 2 1 Danger classification The safety precautions in the manual are always prese...
Страница 8: ...ons that could arise when objects or equipment are damaged if no measures are taken to prevent this NOTE Information on important special features TIP User tips and information 2 2 Pictograms on Test...
Страница 9: ...in this manual are observed In particular observe the following Connect the device only to line voltage that confirms to the power specifi cation given on the type label on the back of the test equipm...
Страница 10: ...ion can be found in the acci dent prevention regulations Also observe all the safety measures for additional devices used together with the test system 2 8 Accident prevention regulations When dealing...
Страница 11: ...agency and or your dealer 3 2 Delivery contents The standard delivery contains the basic unit as well as several attachments and accessories 3 2 1 Standard accessories One power cable 3 2 2 Documenta...
Страница 12: ...ower cord of the equipment is located on the back of the equipment The power input is secured with a delayed action fuse for details refer to chapter 5 3 Protection The power plug and outlet must have...
Страница 13: ...ntrol connector The CONTROL connector is an input port for the function generator it can be directly connected to the appropriate connector at the function generator card of your NSG series To benefit...
Страница 14: ...ulator can be described as U OUTPUT Vprog x GAIN The GAIN can either be set to 7 or 1 Ilim is the analog control of the current limit The input is 1 10 V which equals a current limit of 1 10 A CAUTION...
Страница 15: ...OTE Information about the power output connectors See the hardware guide of the appropriate test system for more details 3 4 2 2 The sense output connectors The SENSE connectors may be connected to co...
Страница 16: ...ARD This is the normal operating mode with a good com promise between stability and bandwidth The bandwidth in this selection is approximately 40 kHz CAPACITIVE This mode is specifically designed for...
Страница 17: ...oltage GAIN LOW x1 Indicates a gain of one 1 V in will result in 1 V output voltage 4 3 The CURRENT LIMIT LED This LED indicates that the current limit has been reached 4 4 The ERRORS LEDs POWER FAIL...
Страница 18: ...l down the amplifier NOTE The active COMPENSATION and the active GAIN LED are blinking additionally If the output signal is switched off because the amp lifier detected over temperature or a power err...
Страница 19: ...application please use compensation mode CAPACITIVE 5 Applications 5 2 Voltage variations for starting profiles The PA 5740 series is often used for starting profile simulation pulse 4 and variants In...
Страница 20: ...and drops applications where 10 s rise times are specified For this application please use compensation mode STANDARD 5 4 Voltage ripple and sine wave noise simulations The PA 5740 is also commonly us...
Страница 21: ...10 HVPSU Power entry Battery switch Controller CT 5610 FG 5620 Blank Slot TC 5650 PA 5640 DS 5630 NSG 5600 PC IEEE PA 5840 PA 5840 Bat Aux Coil EUT output PM output SVI output Auxiliary input Sense ou...
Страница 22: ...ly by qualified personnel Before moving the equipment even over a short distance you must first turn it off and disconnect it from the mains Remove any fixturing devices and or test objects Also disco...
Страница 23: ...age Ueff Primary current Ieff PA 5740 75 100 V 1 100 V 12 5 A PA 5740 75 120 V 1 120 V 10 A PA 5740 75 230 V 1 230 V 6 3 A 6 3 1 Fuses The fuses are placed in the mains voltage selector To exchange a...
Страница 24: ...tery simulators Carefully loosen the drawer from the input connector assembly using a screwdriver and turning it slightly in both directions as shown in the pictures below Pull out the drawer from the...
Страница 25: ...25 Remove the defect fuse Remove the defect fuse CAUTION Risk of destruction by wrong fuses Use the following fuse types 5 x 20 mm 6 A time lag...
Страница 26: ...26 PA 5740 Automotive battery simulators Push the drawer back in until it is fixed to the input connector assembly again Now reconnect the PA 5740 to the mains...
Страница 27: ...General PA 5740 Forward voltage gain 7 1 switchable Bandwidth 3 dB DC to 40 kHz standard to 150 kHz high freq Overtemperature shutdown Thermal sensors trip at 80 C warning and 90 C output shut off Su...
Страница 28: ...edance 10 kOhm U Input gain x1 1 V 1 V output gain x7 1 V 7 V output I Input 10 V 10 A Display for output voltage 0 to 60 V 1 digit 2 of RMS Reading Display for output current 0 to 10 A continuous 1 d...
Страница 29: ...6 3 A 10 or 12 5 A Connector for line supply 1 phase socket Connector for output power 2 x 4 mm banana female Connector for output power 2 x 2 mm banana female sense Standard compliance Safety IEC 10...
Страница 30: ...30 PA 5740 Automotive battery simulators 7 3 Pictures 7 3 1 Front view 7 3 2 Rear view...
Страница 31: ...31 8 Declaration of conformity CE...
Страница 32: ...6 10 8460 8080 F 86 10 8460 8078 chinasales teseq com Germany Teseq GmbH T 49 30 5659 8835 F 49 30 5659 8834 desales teseq com Singapore Teseq Pte Ltd T 65 6846 2488 F 65 6841 4282 singaporesales tese...