19
4.2.4 Measurement adapters
The measurement adapter type MD 101 as per IEC / EN 61000-4-2 (2001) serves
to verify pulse amplitudes and pulse shapes. It is designed for mounting in the
side wall of a Faraday cage in which an oscilloscope has been installed. This
measurement adapter has the flat impedance curve to well over 1 GHz that is
necessary for the purpose.
Use of this adapter is only worthwhile in conjunction with a test rig that is laid
out in strict conformity with the relevant standard (see section "Verification of
pulse data").
Coax connector
Contact surface
(target)
Mounting flange
MD 103 ("Pommerenke" target) is a more advanced coaxial measuring target
with flat response characteristics up to the multi-GHz range. It may be used
instead of MD 101.
MD 103 with INA 103