CBA 400M-260 OPERATING MANUAL 

 

 

SECTION 3 

OPERATION 

 
 

FRONT PANEL 

STANDBY/OPERATE SWITCH 

Push button toggles between standby and operate modes 

POWER INDICATOR 

Green: 

Flashing green indicates standby mode. 

Continuous green indicates operate mode 

INTERLOCK INDICATOR 

Yellow: 

Illuminated if the external interlock (rear panel) has been activated. Amplifier will be in non operating 
mode. 

FAULT INDICATOR 

Red: 

Should the amplifier be subject to a failure in the cooling system (either by a fan failure, inadequate 
air supply or excess ambient temperature) this indicator will illuminate and the amplifier gain stages 
will  all  be  turned  off.    This  action  is  non-latching,  so  the  gain stages will come on again when the 
amplifier has cooled down. 

LOCAL LOCKOUT INDICATOR

 

Yellow: 

Illuminated  if  local  lockout  has  been  implemented  by  external  software,  Standby/operate  button  is 
disabled. 

 

This indicator is only present on models with the optional USB control interface 

RF INPUT (depending on model) 

The  RF  input  will  accept  a  signal  from  an  RF  generator.    This  input  must  be  within  the  operating 
frequency  range  of  freq.  An  amplitude  of  up  to  0dBm  will  be  sufficient  to  saturate  the  amplifier.  
Operation  outside  the  specified  frequency  range  should  not  be  attempted,  and  may  subject  the 
amplifier to undue internal stress. 

RF OUTPUT (depending on model) 

This connector must be suitably terminated at all times during operation.  Ensure that the cable and 
load are all capable of handling the power available. On no account operate the amplifier without a 
proper  termination  or  defective  cables  or  connectors.    The  centre  conductor  of  the  RF  output 
represents a severe burn hazard to personnel. 

AIR INLET 

The  amplifier  depends  upon  a  free  air  supply  for  cooling.    Ensure  that  the  front  air  inlet  is  not 
restricted. 

 

Содержание CBA 400M-260

Страница 1: ...CBA 400M 260 OPERATING MANUAL 1 OPERATING MANUAL CBA 400M 260 10kHz to 400MHz 260 watt AMPLIFIER Aug 2013 2013 Teseq Limited All Rights Reserved...

Страница 2: ...rchase price paid for the defective product Transportation of the defective product or part to the factory or service centre is to be pre paid by the customer All products that are replaced will becom...

Страница 3: ...L 3 CONTENTS SAFETY INFORMATION 4 SECTION 1 INTRODUCTION 5 CBA 400M 260 INTRODUCTION 5 SECTION 2 UNPACKING AND INSTALLATION 6 UNPACKING 6 INSTALLATION 6 SECTION 3 OPERATION 7 FRONT PANEL 7 REAR PANEL...

Страница 4: ...tective equipment required by local regulations This apparatus is of Installation Category 2 WARNING This apparatus is capable of delivering harmful levels of radio frequency power Ensure at all times...

Страница 5: ...nerate high levels of RF energy it is not intended for use in a residential environment Although harmful levels of RF power are not emitted by the amplifier poorly screened or matched cables can radia...

Страница 6: ...400M 260 Operating Manual this document Calibration Report If any signs of damage are found no attempt should be made to install the instrument which should be returned to Teseq EMC Systems or their...

Страница 7: ...has been implemented by external software Standby operate button is disabled This indicator is only present on models with the optional USB control interface RF INPUT depending on model The RF input w...

Страница 8: ...normal operation condition as delivered INPUT OUTPUT CONNECTORS depending on model The RF input and output connectors may optionally be placed on the rear panel if selected at the time of ordering FA...

Страница 9: ...afety Conducted and Radiated Emissions EN61326 Class A Conducted and radiated immunity EN61326 1997 Table 1 Mains harmonic currents EN61000 3 2 Voltage fluctuations and flicker EN61000 3 3 Safety EN61...

Отзывы: