4.2 The system stop button
In case, an EUT needs to be exchanged frequently, the optional safety banana
plug set INA 163 gives the possibility to connect the EUT in an easy and safe
way. With this option the max. current consumption of the EUT must not exceed
32 A.
DANGER! The “STOP” button does not disconnect the
tester from the line voltage.
OFF
The system is completely powered off
ON
The system is in standby mode when first starting the system or after
an error condition. In order to start the system the first time, or after
an error condition, the key must temporarily be placed in the “START”
position
START (Momentary) Used to enable the amplifier output
CAUTION! For safety, the “POWER” switch is keyed. The
key can be removed in either the “ON” or “OFF” posi-
tion. Please do not lose this key, as the system will be
unusable without it!