Mains input
Mains input is via a pre-wired IEC 60309 3-phase plug.
Star configured supplied with a 5 pin plug.
Delta configured supplied with a 4 pin plug.
If the plug requires rewiring brown and 2 black wires are 3-phase line, blue is
neutral when used in star (unused in delta configuration) and green/yellow for
earth.
The amplifier safety mechanism is a circuit breaker. The switch unit is supplied
from the power unit via the power breaker, located on the rear panel of the
power unit.
Safety interlock
This connector may be left open-circuit if no safety interlock is required, or
other safety methods are in place. The amplifier will operate satisfactorily. To
operate the safety interlock, short-circuit this connector. Current drawn from
this connector under short circuit conditions will typically be 2.8 mA.
Air outlets
The air outlets for the amplifier must have unrestricted access for proper opera
-
tion.
Do not place the back of the amplifier less than one metre from a wall or other
obstruction.