RF input (rear panel of centre unit)
The RF input will accept a signal from an RF generator. This input must be within
the operating frequency range of 10 kHz to 100 MHz. An amplitude of up to 0
dBm will be sufficient to saturate the amplifier. Operation outside the specified
frequency range should not be attempted, and may subject the amplifier to
undue internal stress.
RF output (rear panel of centre unit)
This connector must be suitably terminated at all times during operation.
Ensure that the external N type connector, 50 ohm co-axial cable and load are
all capable of handling the power available, which can exceed 1 kW. Do not
operate the amplifier without a proper termination or with defective cables or
connectors. The centre conductor of the RF output represents a severe burn
hazard to personnel.
Do not remove the output connector during operation, as
a self-sustaining arc may be struck, which will damage
the output connector, and create a fire hazard.
Air inlets
The amplifier units, input/output unit a power unit all depend upon a free air
supply for cooling. Ensure that the front air inlets are not restricted.
Dust can rapidly build up on the air inlets, these should be checked and cleaned
at regular intervals to ensure continued reliable operation of the amplifier. Inter
-
vals should not be longer than six months but may be required more often in
dusty environments.