2. Operation
17
[Figure 3] Field Generation and Field Pattern
<Example>
Connect the RF output of a signal generator to the input port of TC-5062C with a cable.
Set the signal generator frequency (between 100 MHz to 6 GHz) and the signal level to
220 mV. The E-field developed at the test point inside TC-5062C is then:
E = 0.22(V) / 0.22(meter) = 1 (Volt/meter).
If the signal generator output is decreased to 2.2 uV, the E-field inside TC-5062C
becomes 10 uV/meter at the center of the test volume.
L (meter)
V(volt)
E (volt/meter)
DUT
E
(b) Field Pattern (Top View)
(a) Field Generation
Signal
Generator
深圳德标仪器