T-200 Series UPS User Manual 

2

 

 

II. INTRODUCTION 

 
 

Thank you for selecting this uninterruptible power supply (UPS). To choose the T-200 series as your 
equipment protector was a wise investment. It includes many features to protect your critical equipments. 
 
The T-200 series UPS system is connected between mains and critical loads, such as computer systems, 
telecommunication systems, computerized instruments etc.  

 

The advantages of using UPS: 
 

 

Increased power quality: 

The UPS has its own internal voltage and frequency regulator circuits which ensure that its output is 
maintained  within  close  tolerances  independent  of  voltage  and  frequency  variations  on  the  mains 
power lines. 

 

 

Increased noise rejection: 

By rectifying the input ac power to dc power, and then converting it back to ac, any electrical noise 
that may present on the input mains supply line is effectively isolated from the UPS output, therefore 
the critical load sees only clean power. 

 

 

Power blackout protection: 

If the mains power fails, the UPS continues to power the critical load from its battery source, leaving 
the load immune from power disturbances. 
 
 
 
 

2.1 System Description 

 
Features : 

 

On-line

 technology with pure 

sine wave

 output. 

  PWM and IGBT technology. 

  Microprocessor controlled main controller board. 

  Static (STS) and maintenance by-pass. 

  LCD (Liquid Crystal Display) display.  

  Alarm history ( Memory for max. 64 alarms. ) 

  Automatic battery testing (optional). 

  High quality maintenance-free lead-acid type batteries. 

  High nonlinear load capacity, special for computers. 

 

Accessories :

 

o

  Optional UPS monitoring software (T-MON, RUPS

 

, RUPSII

 

, UPSILON

 

) SNMP devices, 

compatible to any operating system. 

 

o

  Remote Monitoring Panel (RMP) available : You can observe the UPS status and parameters 

without using a computer at a remote location up to 200 meters away ( via RS485 interface). 

 

 

o

  UPS Port Sharer available  

 
T-200 Series Uninterruptible Power  Supplies (UPS) are advanced true On-Line  Sine  wave devices  with 
static transfer switch which provide reliable, regulated, transient-free AC power to sensitive equipment.  
 
Since  the  UPS  is  a  true  On-Line  system,  conditioned  power  is  provided  continuously  to  the  connected 
equipments.  Unlike  standby  power  systems,  the  UPS  is  constantly  regulating  and  filtering  the  output 
power. When incoming power is interrupted, the UPS protects the computers instantaneously without any 
transfer time. 
 
The T-200 Series

 

has high non-linear load capability (i.e. Crest Ratio 3:1) and this is suitable for powering 

special loads such as switching power supplies or highly capacitive inputs like computers. 
 

Содержание T-200 Series

Страница 1: ...USER MANUAL T 206 6 kVA T 207 7 5 kVA T 210 10 kVA T 200 SERIES UNINTERRUPTIBLE POWER SUPPLIES 3 Phase Input 1 Phase Output...

Страница 2: ......

Страница 3: ...rupted 9 4 4 Operator Control Panel 9 4 4 1 Push Buttons 10 4 4 2 First Message Line Of The LCD 10 4 4 3 Second M L ALARMS Of The LCD 11 4 5 Automatic Battery Test System optional 11 V OPTIONAL EQUIPM...

Страница 4: ...ed service personnel The output may be energized when the unit is not connected to a mains supply Risk of electric shock hazardous live parts inside this unit are energized from the battery supply eve...

Страница 5: ...wave output PWM and IGBT technology Microprocessor controlled main controller board Static STS and maintenance by pass LCD Liquid Crystal Display display Alarm history Memory for max 64 alarms Automa...

Страница 6: ...of power transistor IGBT and pulse width modulation PWM Inverter converts dc bus voltage into an alternative voltage like line voltage And provides this voltage and frequency being fixed Static Trans...

Страница 7: ...Voltage 220 230 240 VAC Output Voltage Tolerance 1 Output Frequency 50 Hz Output Frequency Tolerance Line Synchronized 1 Free Running 0 2 Efficiency 100 Load 85 87 Crest Factor 3 1 Overload capacity 1...

Страница 8: ...Figure 2 2 1 6 7 5 10 kVA Rear view 6 7 5 10 kVA Model S Rear view Battery Fuse AC Output Terminals DB9 Port PK1 On Off Switch AC Output 6 7 5 10 kVA Model A Rear view Battery Fuse DB9 Port PK1 On Off...

Страница 9: ...Optional 3 2 Location Selection The UPS is designed to be installed in a protected environment The following conditions should be prohibited 1 Blocking the airflow intake and outlet It is recommended...

Страница 10: ...tected by a circuit breaker 1 Before connecting AC and DC power to the UPS make sure that the On Off Switch PK1 Main Switch and battery fuse on the rear panel are in the 0 position OFF 2 Connect the A...

Страница 11: ...audible alarm will sound intermittently Now the output receptacles are supplied from the battery source 4 Connect the power again and see that LINE FAILURE alarm is off 5 Now your UPS is ready to oper...

Страница 12: ...cords into outlets 4 3 When Utility Power Is Interrupted In case the utility power is interrupted the UPS converts the built in battery source to output terminals immediately to protect your critical...

Страница 13: ...s message the sound button enables disables sound alarm SOUND ON SOUND OFF Audible alarm is active Audible alarm is not active disabled by the user Each press to this button will change the status BAT...

Страница 14: ...out of tolerance ONLINE MODE UPS operating mode is ONLINE mode ECONO MODE optional This message shown the alternate operating mode is active OFFLINE 4 5 Automatic battery test system optional There ar...

Страница 15: ...unicate so that the computer system is warned of impending UPS shutdown Software T MON RUPS RUPSII UPSILON 2000 and SNMP devices is available for most operating systems and is supplied with a signalin...

Страница 16: ...ftware supplied with the module or it is possible to monitor the UPS through an Internet Browser It is possible to shutdown the servers or users with Client mate Software that communicates with SNMP m...

Страница 17: ...system from several different locations at the same time 5 5 UPS Port Sharer Multiple server shut down unit Using one of this units you can automatic shut down of 4 8 servers or PC where without LAN...

Страница 18: ...T 200 Series UPS User Manual 15...

Страница 19: ...T 200 Series UPS User Manual 16 Connection Diagram Of The RMP COM1 T MON...

Страница 20: ...iced only by authorized people In case of a persistent failure or problem properly turn off the unit first Then review the following check list Be prepared to answer the questions before calling the s...

Страница 21: ...not apply if the product has been subjected to physical abuse improper installation unauthorized service or modification 2 The sole responsibility of corporation under this warranty shall be limited t...

Страница 22: ...AGKK3802 09 2013...

Отзывы: