![Terrasat Rx 1+1 Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883075.webp)
RS485
|
5-13
11. Press the 2 key.
12. Type the trap host IP address
Note:
Community strings cannot be set from the hand-held terminal.
To configure SNMP from the Web pages
1. Connect to the Rx 1+1 system with a Web browser
The default IP address is
http://192.168.1.254
.
2. Type the password.
The default password is
1234
.
3. Select the Interface Configuration tab
4. Enable SNMP, SNMP Trap, host trap IP, and set passwords, if desired.
The default is public, private, and trap.
5. Click
Save Settings
to ensure that your changes are saved.
Note:
Changing the SNMP passwords requires a firmware reboot.
MIBs
Management information bases (MIBs) are hierarchical virtual databases used to
manage the devices in a communications network. The following MIBs are provided
for the SNMP management station:
•
TERRASAT-RX1PLUS1-MIB.MIB
•
TERRASAT-SMI.MIB
•
TERRASAT-TC-MIB.MIB
•
TERRASAT-TRAPDEF-MIB.MIB
RS485
The RS485 interface is intended primarily as a network management system (NMS)
interface accessed by an NMS program. You can also access the RS485 interface with
the host computer by using the host computer’s on-board RS485 card or by using an
external RS232 to RS485 adapter. You can communicate with the Rx 1+1 system
across RS485 through ASCII.
The RS485 interface is a standard two-wire interface (DATA+ and DATA-). The baud
rate is programmable to 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200
baud. The data is transmitted asynchronously as 8 bits, no parity, no flow control, and
one stop bit.
Содержание Rx 1+1
Страница 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Страница 6: ...iv ...
Страница 10: ...viii This page intentionally left blank for double sided printing ...
Страница 12: ...x This page intentionally left blank for double sided printing ...
Страница 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Страница 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Страница 78: ...5 16 Monitor and Control Features and Functions This page intentionally left blank for double sided printing ...
Страница 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Страница 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Страница 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Страница 160: ...F 2 Reference Drawings and Component Specifications Figure F 1 Fabrication Drawing FBD 21012 XXXX Rev A ...
Страница 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Страница 162: ...F 4 Reference Drawings and Component Specifications Figure F 3 Assembly Drawing ASD 10713 0010 Rev A ...
Страница 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...
Страница 164: ...F 6 Reference Drawings and Component Specifications Figure F 5 Outline Drawing OLD 10801 0005 Rev A ...
Страница 166: ...F 8 Reference Drawings and Component Specifications This page intentionally left blank for double sided printing ...