![Terrasat Rx 1+1 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/terrasat/rx-1-1/rx-1-1_operation-manual_1089883064.webp)
5-2
|
Monitor and Control Features and Functions
To initiate an RS232 session,
1. Connect a 10-pin to DB9F cable between the computer and the Rx 1+1 system.
contains a drawing for fabricating a cable.
2. Activate a terminal emulation program such as HyperTerminal.
See
for information about how to connect using HyperTerminal.
3. Type four single quotes (for example,
‘ ‘ ‘ ‘
), and then press Enter.
Although the default mode is RS232, typing the four single quotes upon activating
a terminal emulation program ensures that the unit is in RS232 mode.
4. Type the password command
CPE=1234
and then press Enter.
You can now use the ASCII commands described in
to configure and monitor the Rx 1+1 system.
Note:
The password entered in
is the factory default password. If you have changed
the password, type that value instead.
The RS232 port is shared with the hand-held terminal.
Hand-held Terminal
The hand-held terminal (HHT) shown in
is an optional item that can be
used to access the Rx 1+1 system via the J1 connector on the interface module. No
additional configuration is needed for proper operation of the HHT.
Содержание Rx 1+1
Страница 1: ...Receive Redundant Systems Operations Manual 24 Hour Technical Support 1 408 782 2166 ...
Страница 6: ...iv ...
Страница 10: ...viii This page intentionally left blank for double sided printing ...
Страница 12: ...x This page intentionally left blank for double sided printing ...
Страница 20: ...1 6 Introduction This page intentionally left blank for double sided printing ...
Страница 36: ...2 16 Functional Description This page intentionally left blank for double sided printing ...
Страница 78: ...5 16 Monitor and Control Features and Functions This page intentionally left blank for double sided printing ...
Страница 84: ...6 6 Troubleshooting This page intentionally left blank for double sided printing ...
Страница 145: ...Screen Shots E 13 IDC Low Threshold Sets the lowest permitted level down to 100 Ma ...
Страница 158: ...E 26 Web Pages This page intentionally left blank for double sided printing ...
Страница 160: ...F 2 Reference Drawings and Component Specifications Figure F 1 Fabrication Drawing FBD 21012 XXXX Rev A ...
Страница 161: ...Reference Drawings F 3 Figure F 2 Fabrication Drawing FBD 20786 XXXX Rev A ...
Страница 162: ...F 4 Reference Drawings and Component Specifications Figure F 3 Assembly Drawing ASD 10713 0010 Rev A ...
Страница 163: ...Reference Drawings F 5 Figure F 4 Top View of Rx 1 1 System Showing Connector Locations ...
Страница 164: ...F 6 Reference Drawings and Component Specifications Figure F 5 Outline Drawing OLD 10801 0005 Rev A ...
Страница 166: ...F 8 Reference Drawings and Component Specifications This page intentionally left blank for double sided printing ...