5.4.

  Transport Streams

One channel at a time can be configured in this page. Select proper channel from the list at „Choose input channel“ 

combobox (see Figure 11 “Transport streams page”).

Figure 11. Transport streams page

A list of services in the selected channel will appear. „List of services“ table shows a list of available services. Icon before 

th

e service name indicates service type. Bitrate of each service is measured in real time. Services that currently are not 

running will be displayed as grayed. They can be selected and will be outputted normally when the services starts to running. 

„LCN“ field is a Logical Channel Number. Every service can have a „channel number“ and TV will sort channels according to 

it. Just ensure, that all services in all channels have different numbers. Value 0 means, that LCN for that service is not used 

at all and TV will sort these channels according to it’s own rules. If channel numbers are added, but TV does not recognize 

it, check the following:

- If TV supports LCN?

- If Network ID and Original Network ID values are valid for the country, which is selected on TV?

„Enable“ dropbox enables the service to the selected output.

“Descramble” checkbox enables or disables descrambling.

Press onto „+“ sign and service information will be extended (see Figure 12 "Service details").

Figure 12. Service details

“Service title“ and “Service provider“ can be edited (multilanguage character support). „Scrambled flag“ will be inserted 

into SDT (Service Description Table). Unchecking this checkbox will not descramble the content. It only carries information 

about the scrambling status of the service. 

"Service type": this is an 8-bit field specifying the type of the service. The assignment of service type value for a Service 

is described in EN 300 468.  It shall be coded according to Figure 13. 

"Parental control": this selection enables ability to restrict certain content viewable by the user. For example, parental control 

field is set to "Less than 6 years", than all content with maturity rating above 6 years old will be filtered out.

Содержание S3C32VB

Страница 1: ...Vers 1 02 32 channels DVB S S2 to 16 32 DVB C transmodulators S3C32VB S3C32WB User s manual EN ...

Страница 2: ...connect plugs from mains socket The mains sockets must be easily accessible The headend shall not be exposed to dripping or splashing water and no objects filled with liquids such as vases shall be placed on it Avoid placing device next to the central heating components and in areas of high humidity No naked flame sources such as lighted candles should be placed on headend If the device has been k...

Страница 3: ...N 2 DC OUT 2 EN50607 1Amax 0 13 18 V RF TEST 20 dB RF OUT 8 10 11 14 15 12 13 Bottom view Front view S3C32WB 32 mux DVB S S2 32 DVB C Transmodulator POWER SUPPLY 1 STATUS DC OUT 2 STATUS DC OUT 1 POWER SUPPLY 2 HEADEND ADDR STATUS 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 RESET 8 3 4 7 1 2 5 6 17 12 13 14 15 16 ...

Страница 4: ...addressing indicator It blinks on when the device is being accesed via Web interface 2 HEADEND STATUS error indicator Red light indicates that at least one error exists at the moment 3 STATUS DC OUT 1 indicates LNB1 powering status 4 STATUS DC OUT 2 indicates LNB2 powering status 5 STATUS POWER SUPPLY 1 indicates correct DC voltage from power supply PS1 6 STATUS POWER SUPPLY 2 indicates correct DC...

Страница 5: ...n Enter the user name and password and click on Login button NOTE the default password admin can and must be changed as explained in the section 5 11 5 User management During initial configuration you need to change the default control interface TCP IP configuration as explained in the section 5 9 IP settings NOTE If you are using Internet Explorer Web browser supported versions are version 10 or ...

Страница 6: ...be displayed Make sure that Ethernet router is configured properly to pass SSDP packets 239 255 255 250 1900 and 239 255 255 246 7900 Also make sure that all devices are connected to the same Ethernet network Diagnostic information table It displays all device errors and comments how to eliminate them Figure 4 Diagnostic information table with errors 5 3 RF inputs Figure 5 Input 1 Input 2 table DV...

Страница 7: ...11 725 MHz DiSEqC then DISEQC commands are used to select the satellite Possible commands Satellite A Satellite B Satellite C Satellite D Vertical or Horizontal polarization dSCR first select source type as shown in Figure 6 then select dSCR SCR mode Device must have direct connection to Unicable multiswitch or LNB Next select SAT input and User band type in frequencies symbol rate press Update bu...

Страница 8: ... only if the device has synchronized with the input signal Modulation standard detected standard of the input signal Possible values of the standard DVB S DVB S2 Frequency intermediate frequency for DVB S S2 at the device input Modulation modulation scheme of the input signal Possible values of the modulation scheme QPSK 8PSK for DVB S S2 FEC forward error correction SNR RF signal noise ratio at t...

Страница 9: ...numbers are added but TV does not recognize it check the following If TV supports LCN If Network ID and Original Network ID values are valid for the country which is selected on TV Enable dropbox enables the service to the selected output Descramble checkbox enables or disables descrambling Press onto sign and service information will be extended see Figure 12 Service details Figure 12 Service det...

Страница 10: ...e 3 0x1D H 264 AVC frame compatible plano stereoscopic HD NVOD time shifted service see note 3 0x1E H 264 AVC frame compatible plano stereoscopic HD NVOD reference service see note 3 0x1F HEVC digital television service see note 4 0x20 to 0x7F reserved for future use 0x80 to 0xFE user defined 0xFF reserved for future use NOTE 1 MPEG 2 SD material should use this type NOTE 2 MPEG 1 Layer 2 audio ma...

Страница 11: ...The 2nd table in the page describes Transport stream ID and Original network ID of each channel see Figure 15 Each stream in a network must have unique ID called Transport stream ID An Original_Network_ID is defined as the unique identifier of a network It can be linked to Network ID or used value from this location http www dvbservices com identifiers original_network_id page 1 Figure 15 Transpor...

Страница 12: ...ises You can easily filter out needed output channels by selecting needed output in table TS Info This lets you quickly view and setup LCN for every channel also check your Output bitrate and ensure that it is not overflowing Figure 17 TS Info table ...

Страница 13: ...l precise attenuator up to 2 5 dB in step of 0 5 dB Press Update to change settings In case if any modulation parameter was changed all channels will be restarted with new settings Exception is Attenuator changes in this parameter will not restart the modulator Figure 18 DVB C output parameters 16 32 independent QAM modulators can be setup in this section There is no requirement for channels to be...

Страница 14: ...stem see Figure 19 IP settings table IP parameters will be updated immediately after pressing Update button and redirect to new location NOTE Press the RESET and default IP button for more than three seconds to set default IP address of the control Ethernet interface see Figure 1 External view of the device Figure 19 IP settings table 5 10 E mail settings The device can send e mail reports if erro...

Страница 15: ...on to send the file to the device It will take several seconds to update all parameters after file upload After that device will function with new configuration No restart is required 5 11 4 Firmware upgrade Device firmware can be upgraded via web browser Press the Click to select file button and select firmware binary file If valid file was selected a version number of new firmware will be displa...

Страница 16: ...d or user access account for another person you take full responsibility for all device settings modifications made by that person or anyone else they may give the password to 5 11 6 Restore defaults All parameters will be restored back to factory defaults after confirmation The exception IP address and users these parameters will be unchanged To restore IP address and system password to system de...

Страница 17: ...5 11 10 Language Device control panel supports several preinstalled languages A change of language requires system restart Note that all previously logged records will remain in previous language Additional languages can be installed under request Contact our distributors for such possibility 6 Regions Device supports several preinstalled regions Region can be changed without restarting the device...

Страница 18: ... MHz by 100 kHz step channel allocation independent output level per carrier impedance max 90 dBµV 75 Ω total output level adjustment 15 dB by 1 dB step carrier output level adjustment 2 5 dB by 0 5 dB step MER 43 dB modulation DVB C QAM16 QAM32 QAM64 QAM128 QAM256 channel bandwidth symbol rate 4 8 3 MHz 3 5 7 2 MS s roll off 15 signal processing EN 300 429 ITU T J 83 A Annex A test point 20 dB TS...

Страница 19: ...TERRA UAB Draugystes str 22 LT 51256 Kaunas Lithuania Tel 370 37 31 34 44 fax 370 37 31 35 55 E mail sales terraelectronics com www terraelectronics com ...

Отзывы: