background image

1

 

1.

  Product description

The transmodulator is designed for digital transmodulation with Transport Stream Processing. Device enables services 

filtering, remultiplexing, modifying SI (Service Information), generating NIT (Network Information table), LCN (Local Channel 
Number), restamping PCR (Program Clock Reference). All of the configurations can be changed using the Web Interface.

The transmodulator can be used as a stand alone unit - headend 

with redundant power supply (PS) to increase reliability 

of supply voltages.

S3C32VB

 – headend with 32 DVB-S/S2 input channels and 16 agile DVB-C output channels.

S3C32WB

 – headend with 32 DVB-S/S2 input channels and 32 agile DVB-C output channels.

The products are intended for indoor usage only.

 

2.

  

Safety instructions

Installation of the 

headend must be done according 

IEC60728-11 and national safety standards.

Headend

 is powered from mains 230 V~. This voltage is dangerous to life. 

Any repairs must be done by a skilled personnel only. 
To avoid the electric shock follow these instructions:

   Do not plug transmodulator into the mains supply if the power cord or plug is damaged.

   To disconnect the headend

 from the mains completely, disconnect plugs from mains socket

.

   The mains sockets must be easily accessible.

   The headend

 shall not be exposed to dripping or splashing water and no objects filled with 

 

liquids, such as vases, shall be placed on it.

   Avoid placing device next to the central heating components and in areas of high humidity.

   No naked flame sources, such as lighted candles, should be placed on 

headend.

   If the device has been kept in cold conditions for a long time, keep it in a warm room no less than 2 

 

hours before plugging into the mains.

   D

o not insert any objects into ventilation openings

.

   T

he ventilation should not be impeded by covering the 

headend

 with items, such as newspapers, 

       table-cloths, curtains

.

 

 This

 product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must be recycled  

 

 

  or discarded according to applicable local and national regulations.

   Equipment intended for indoor usage only.
 

This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm EN62368-1, 

 

RoHS norm EN50581.

  

Protective earthing. Connect to protective earthing bar. 

 

This product is in accordance wit

h Custom Union Technical Regulations: “Electromagnetic compatibility of technical 

 

equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 004/2011.

 

This product 

is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia.

Содержание S3C32VB

Страница 1: ...Vers 1 02 32 channels DVB S S2 to 16 32 DVB C transmodulators S3C32VB S3C32WB User s manual EN ...

Страница 2: ...connect plugs from mains socket The mains sockets must be easily accessible The headend shall not be exposed to dripping or splashing water and no objects filled with liquids such as vases shall be placed on it Avoid placing device next to the central heating components and in areas of high humidity No naked flame sources such as lighted candles should be placed on headend If the device has been k...

Страница 3: ...N 2 DC OUT 2 EN50607 1Amax 0 13 18 V RF TEST 20 dB RF OUT 8 10 11 14 15 12 13 Bottom view Front view S3C32WB 32 mux DVB S S2 32 DVB C Transmodulator POWER SUPPLY 1 STATUS DC OUT 2 STATUS DC OUT 1 POWER SUPPLY 2 HEADEND ADDR STATUS 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32 RESET 8 3 4 7 1 2 5 6 17 12 13 14 15 16 ...

Страница 4: ...addressing indicator It blinks on when the device is being accesed via Web interface 2 HEADEND STATUS error indicator Red light indicates that at least one error exists at the moment 3 STATUS DC OUT 1 indicates LNB1 powering status 4 STATUS DC OUT 2 indicates LNB2 powering status 5 STATUS POWER SUPPLY 1 indicates correct DC voltage from power supply PS1 6 STATUS POWER SUPPLY 2 indicates correct DC...

Страница 5: ...n Enter the user name and password and click on Login button NOTE the default password admin can and must be changed as explained in the section 5 11 5 User management During initial configuration you need to change the default control interface TCP IP configuration as explained in the section 5 9 IP settings NOTE If you are using Internet Explorer Web browser supported versions are version 10 or ...

Страница 6: ...be displayed Make sure that Ethernet router is configured properly to pass SSDP packets 239 255 255 250 1900 and 239 255 255 246 7900 Also make sure that all devices are connected to the same Ethernet network Diagnostic information table It displays all device errors and comments how to eliminate them Figure 4 Diagnostic information table with errors 5 3 RF inputs Figure 5 Input 1 Input 2 table DV...

Страница 7: ...11 725 MHz DiSEqC then DISEQC commands are used to select the satellite Possible commands Satellite A Satellite B Satellite C Satellite D Vertical or Horizontal polarization dSCR first select source type as shown in Figure 6 then select dSCR SCR mode Device must have direct connection to Unicable multiswitch or LNB Next select SAT input and User band type in frequencies symbol rate press Update bu...

Страница 8: ... only if the device has synchronized with the input signal Modulation standard detected standard of the input signal Possible values of the standard DVB S DVB S2 Frequency intermediate frequency for DVB S S2 at the device input Modulation modulation scheme of the input signal Possible values of the modulation scheme QPSK 8PSK for DVB S S2 FEC forward error correction SNR RF signal noise ratio at t...

Страница 9: ...numbers are added but TV does not recognize it check the following If TV supports LCN If Network ID and Original Network ID values are valid for the country which is selected on TV Enable dropbox enables the service to the selected output Descramble checkbox enables or disables descrambling Press onto sign and service information will be extended see Figure 12 Service details Figure 12 Service det...

Страница 10: ...e 3 0x1D H 264 AVC frame compatible plano stereoscopic HD NVOD time shifted service see note 3 0x1E H 264 AVC frame compatible plano stereoscopic HD NVOD reference service see note 3 0x1F HEVC digital television service see note 4 0x20 to 0x7F reserved for future use 0x80 to 0xFE user defined 0xFF reserved for future use NOTE 1 MPEG 2 SD material should use this type NOTE 2 MPEG 1 Layer 2 audio ma...

Страница 11: ...The 2nd table in the page describes Transport stream ID and Original network ID of each channel see Figure 15 Each stream in a network must have unique ID called Transport stream ID An Original_Network_ID is defined as the unique identifier of a network It can be linked to Network ID or used value from this location http www dvbservices com identifiers original_network_id page 1 Figure 15 Transpor...

Страница 12: ...ises You can easily filter out needed output channels by selecting needed output in table TS Info This lets you quickly view and setup LCN for every channel also check your Output bitrate and ensure that it is not overflowing Figure 17 TS Info table ...

Страница 13: ...l precise attenuator up to 2 5 dB in step of 0 5 dB Press Update to change settings In case if any modulation parameter was changed all channels will be restarted with new settings Exception is Attenuator changes in this parameter will not restart the modulator Figure 18 DVB C output parameters 16 32 independent QAM modulators can be setup in this section There is no requirement for channels to be...

Страница 14: ...stem see Figure 19 IP settings table IP parameters will be updated immediately after pressing Update button and redirect to new location NOTE Press the RESET and default IP button for more than three seconds to set default IP address of the control Ethernet interface see Figure 1 External view of the device Figure 19 IP settings table 5 10 E mail settings The device can send e mail reports if erro...

Страница 15: ...on to send the file to the device It will take several seconds to update all parameters after file upload After that device will function with new configuration No restart is required 5 11 4 Firmware upgrade Device firmware can be upgraded via web browser Press the Click to select file button and select firmware binary file If valid file was selected a version number of new firmware will be displa...

Страница 16: ...d or user access account for another person you take full responsibility for all device settings modifications made by that person or anyone else they may give the password to 5 11 6 Restore defaults All parameters will be restored back to factory defaults after confirmation The exception IP address and users these parameters will be unchanged To restore IP address and system password to system de...

Страница 17: ...5 11 10 Language Device control panel supports several preinstalled languages A change of language requires system restart Note that all previously logged records will remain in previous language Additional languages can be installed under request Contact our distributors for such possibility 6 Regions Device supports several preinstalled regions Region can be changed without restarting the device...

Страница 18: ... MHz by 100 kHz step channel allocation independent output level per carrier impedance max 90 dBµV 75 Ω total output level adjustment 15 dB by 1 dB step carrier output level adjustment 2 5 dB by 0 5 dB step MER 43 dB modulation DVB C QAM16 QAM32 QAM64 QAM128 QAM256 channel bandwidth symbol rate 4 8 3 MHz 3 5 7 2 MS s roll off 15 signal processing EN 300 429 ITU T J 83 A Annex A test point 20 dB TS...

Страница 19: ...TERRA UAB Draugystes str 22 LT 51256 Kaunas Lithuania Tel 370 37 31 34 44 fax 370 37 31 35 55 E mail sales terraelectronics com www terraelectronics com ...

Отзывы: