Page 15
Installation – Standard air duct
If there are no two external walls directly available for
installation, the air flow can be conveyed outwards via
insulated air ducts. Our range includes standard air ducts
which can be connected directly to the heat pump without
adaptation.
There are two ways to do this:
Option 1:
This method is used if there are no two external walls
available. As a short circuit may occur between the sup-
ply and exhaust sides with this method, the inlet and out-
let should be positioned as far apart as possible. The unit
can be separated from any shrubbery by fitting dividing
walls if necessary.
Option 2:
This method is equivalent to corner installation. This
method can be used if corner installation is not possible
due to space restrictions or if a gap needs to be bridged
between the heat pump and outlet side.
Air ducts can be connected to the right
and left of the heat pump. Heating and
electrical connections can also be fitted
on both sides.