Quick-Start Operating Guide
USP 797 Modular Cleanroom
©
Copyright 2015 Terra Universal Inc. All rights reserved. • Revised Dec 2019 • Document No. 1800-90
Terra Universal, Inc. • TerraUniversal.com • 800 S. Raymond Ave. • Fullerton, CA 92831 • TEL: (714) 578-6000 • FAX: (714) 578-6020
24
Fan Filter Unit Hard Wiring
WARNING: Disconnect the unit from the electrical power source before attempting any service.
To preserve the UL listing of Terra Fan Filter Units, Terra must configure them for hard-wiring. Cords are dressed to
simplify this operation, which typically does not require an electrician.
1.
Remove the blue prefilter, which
rests on top of the fan filter unit
(Figure 1)
2.
Unscrew metal top panel of the
electrical housing (Figure 2) to
expose wiring junction (Figure 3).
3.
Install cord grip as shown (Figures
4, 5) into appropriate opening.
4.
Thread the AC power cord
through the cord grip and connect
to wire port as shown (Figure 6).
Strip wires and match the colors of
the wiring; green to green, black to
black and white to white. Tighten
retaining screws to fasten wires.
5.
Tighten cord grip to secure AC
power cord.
6.
Replace the metal panel on top of
the electrical housing.
7.
Replace the blue prefilter.
Fig 1
Fig 2
Fig 3
Fig 4
Fig 5
Fig 6