background image

Installation and Operating Guide  

 

Nitrogen Generator 

© 

Copyright 2017 Terra Universal Inc.  All rights 

reserved. • Revised June 2017 • Document No. 1800-47 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020 

 

 

 

 

 

 

 

Flow vs. Purity @ 50° C (122ºF) 

(Based on 77° ambient) 

No. 2700-09 

 

 

No. 2700-11 

 

 

No. 2700-12 

Product Purity 

 

 

Product Purity 

 

 

Product Purity 

Flow in SCFH 

99% 

98% 

97% 

95% 

99% 

98% 

97% 

95% 

99% 

98% 

97% 

95% 

@ 150 psi 

662 

931 

1188  

1714 

181 

254  

325 

469 

16 

22 

28  

41 

@ 135 psi 

578 

815 

1042 

1505 

158 

223 

285 

412 

14

 

19 

25 

36 

@ 125 psi 

522 

737 

943 

1365 

143 

202 

258 

374 

12 

18 

22 

32 

@ 110 psi 

437 

620 

795 

1153 

120 

170 

218 

316 

10 

15 

19 

27 

@ 100 psi 

381 

542 

696 

1012 

104 

148 

191 

277 

9

 

13

 

17 

24 

@ 90  psi  

326 

465 

598 

871 

89 

127 

164 

238 

11 

14 

21 

 

 

Typical Nitrogen Product Flow Rates 

Nm3/h (SCFH) flow at purity —13.8 barg (200 PSI) and 45°C (113°F) 

 
Model 

Purity Level 

95% 

96% 

97% 

98% 

99% 

99.5% 

99.9% 

 

2700-09 

65 

55 

45 

36 

26 

20 

11 

(2461) 

(2084) 

(1715) 

(1350) 

(970) 

(745) 

(407) 

 

 

2700-11 

18 

15 

12 

10 

(673) 

(570) 

(468) 

(369) 

(266) 

(205) 

(110) 

 

2700-12 

1.5 

1.3 

1.1 

0.8 

0.6 

0.5 

0.3 

(59) 

(49) 

(41) 

(32) 

(23) 

(18) 

(10) 

 

Air Feed Requirements 

Nm3/h (SCFH) flow at purity —13.8 barg (200 PSI) and 45°C (113°F) 

 

Model 

Purity Level 

95% 

96% 

97% 

98% 

99% 

99.5% 

99.9% 

 

2700-09 

122 

111 

99 

88 

76 

70 

50 

(4655) 

(4218) 

(3776) 

(3331) 

(2883) 

(2654) 

(1902) 

 

2700-11 

34 

30 

27 

24 

21 

19 

14 

(1274) 

(1156) 

(1034) 

(913) 

(787) 

(726) 

(521) 

 

2700-12 

2.9 

2.6 

2.4 

2.1 

1.8 

1.7 

1.2 

 

(110) 

(99) 

(91) 

(80) 

(68) 

(65) 

(46)

 

Flow Volume Decrease 

Outlet / Inlet flow, By Percentage 

 

At N2 Purity 

Oulet Flow 

 

95% 

 

53% of inlet flow 

 

96% 

 

49% of inlet flow 

 

97% 

 

45% of

 

inlet flow 

 

98% 

 

40% of inlet flow 

 

99% 

 

34% of inlet flow 

 

99.5%   

28% of inlet flow 

 

99.9%   

21% of inlet flow 

Содержание 2700-12B

Страница 1: ... Guide Document No 1800 47 Nitrogen Generator Copyright 2017 Terra Universal Inc All rights reserved Revised June 2017 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Страница 2: ...er impurities in the incoming air line and ensuring a long service life Oil and moisture condensation from the prefilter and coalescing filters exits the system through a 1 4 slip fit connector that can be directed to an in house drain Proprietary Notice This manual pertains to proprietary devices manufactured by Terra Universal Inc Neither this document nor any portion of it may be reproduced in ...

Страница 3: ...mbrane Flow and purity are determined by adjusting either the pressure regulator or flowmeter If consistent outlet pressure is required set the pressure regulator at the desired level and then adjust the flowmeter to achieve the desired flow at your selected pressure The lower the flow rate at any pressure level the higher the product purity The higher the pressure at any flow rate the higher the ...

Страница 4: ...be monitored monthly Under continuous use at 100 PSI filters will operate for approximately two years 20 000 hours Replacing Filter Elements 1 Open the front housing panel of the Nitrogen Generator to expose the filters see Figure 1 2 Rotate the self locking bayonet head 1 8 turn counterclockwise to release it from the bowl see Figure 2 3 Pull the filter element to release it from the head Remove ...

Страница 5: ...ersal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 5 5 0Specifications and Performance Data Model Dimensions Weight uncrated Flowmeter Range 2700 09 24 W x 14 D x 68 25 H 157 lbs 0 400 SCFH 2700 11 24 W x 12 D x 49 25 H 96 lbs 0 100 SCFH 2700 12 20 W x 12 D x 35 25 H 58 lbs 0 20 SCFH Includes polypropylene leveling feet excludes other hardware ...

Страница 6: ...ber filter beds coalesce and remove water droplets Remaining oil content 1 ppm by weight Includes slide indicator to indicate need for filter change liquid level indicator and internal drain ISO 8573 1 Quality Class Solids Class 2 Oil Content Class 4 Coalescing Filter Absolute filtration of 0 01µm particles 99 999 oil removal efficiency Includes slide indicator to indicate need for filter change l...

Страница 7: ... 24 90 psi 326 465 598 871 89 127 164 238 8 11 14 21 Typical Nitrogen Product Flow Rates Nm3 h SCFH flow at purity 13 8 barg 200 PSI and 45 C 113 F Model Purity Level 95 96 97 98 99 99 5 99 9 2700 09 65 55 45 36 26 20 11 2461 2084 1715 1350 970 745 407 2700 11 18 15 12 10 7 5 3 673 570 468 369 266 205 110 2700 12 1 5 1 3 1 1 0 8 0 6 0 5 0 3 59 49 41 32 23 18 10 Air Feed Requirements Nm3 h SCFH flo...

Страница 8: ...tely For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed damage ...