background image

Installation and Operating Guide  

 

Nitrogen Generator 

© 

Copyright 2017 Terra Universal Inc.  All rights 

reserved. • Revised June 2017 • Document No. 1800-47 

Terra Universal, Inc.  •  TerraUniversal.com  •  800 S. Raymond Ave.  •  Fullerton, CA  92831  •  TEL: (714) 578-6000  •  FAX: (714) 578-6020 

 

 

 

 

6.0

 

Warranty 

 
Products  Manufactured  by  Terra:

  Terra  Universal,  Inc.,  warrants  products  that  it  manufactures  to  be  free  from 

defects for a period of 12 months for parts and 90 days for labor, commencing from the date of shipment. Terra’s sole 
responsibility  is  to  repair  or  replace,  at  its  option,  any  part  of  the  product  that  proves  defective  or  malfunctioning 
during this time limit. In some cases, components incorporated in Terra Universal products are covered by additional 

warranties  from  component  manufacturers;  obtain  specific  information  from  Terra  sales  representatives.  This 
warranty  is  void  if  the  equipment  is  abused  or  modified  by  the  customer,  is  operated  outside  Terra’s  operating 

instructions or specifications, or is used in any application other than that for which it is specified. This warranty does 
not include routine maintenance or service procedures, breakage of quartz baths after 60 days, shipping damage, nor 
damage from misuse, intentional or unintentional abuse, neglect, natural disasters, or acts of God.   

 

 

Products  Manufactured  by  Others:

  Terra  Universal,  Inc.,  warrants  that,  to  the  best  of  its  ability,  Terra’s 

representations  of  products  that  are  manufactured  by  others  reflect  the  manufacturer’s  representations,  subject  to 

change without notice. Sole warranty for these products is the original manufacturer’s warranty that is passed forward 
to the purchaser and constitutes the customer’s sole remedy for these products. Detailed warranties for distributed 

products are available through Terra sales representatives. 
 

Freight Shortage or Damage:

 Upon receipt of any equipment from Terra Universal, Inc., customer shall immediately 

unpack and inspect for damage or shortage. The customer shall not accept a damaged package or a short shipment 
until the carrier makes a "damage or shortage" notation on both the carrier's and customer's copy of the freight bill or 
delivery receipt. Service title passes when the shipment is loaded, so customer is responsible for filing and collecting 

a  freight  claim.  Any  replacement  products  must  be  ordered  and  paid  for  separately.  For  Terra's  "Policy  and 
Procedures for Returning Goods," see Terra's Internet site: www.TerraUniversal.com. 
 
Generally,  customers  can  improve  the  chance  of  collecting  on  a  freight  claim  by  following  these  procedures:  1) 
formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify 

condition; 2) notifying the carrier upon discovery of concealed damage and requesting an inspection within 15 days of 
receipt, both in person or phone and following up via mail; 3) keeping the shipment as intact as possible, including 
retaining original packaging materials and keeping the product as close to the original receiving location as possible; 

4) holding salvage for disposition by the carrier. 
 

All  Claims:

  Terra  Universal  expressly  disclaims  all  other  warranties,  expressed  or  implied  or  implied  by  statute, 

including  the  warranties  of  merchantability  or  fitness  for  intended  use.  Terra  Universal  is  not  responsible  for 
consequential or incidental damages arising out of the purchase or use of the products supplied by Terra Universal. 

Terra Universal is not liable for damage to facilities, other equipment, products, property or personnel of others, or of 
their agents, suppliers, or affiliated parties, which is caused or alleged to have been caused by products supplied by 
Terra Universal. In any event or series of events, Terra Universal’s total liability for any and all damages whatsoever 
is limited to the lesser of the actual damages or the original invoice cost  of the items alleged to  have caused the 
damage. The customer’s sole and exclusive remedy for any cause of action whatsoever is repair or replacement of 

the non-conforming products or refund of the actual purchase price, at the sole option of Terra Universal. All claims 
must be made in writing within 90 days of the date the product was shipped. Any claims not made within this time limit 
shall be deemed waived by the customer. Terra Universal is not responsible for any additional costs of repair caused 

by poor packaging or in-shipment damage during return. 
 

Warranty Returns:

 All warranty returns must be authorized in advance by Terra Universal and approved under an 

RMA. Unless approved in advance for good reason, all returns must be in original condition, including all manuals, 
and must be packaged in original packaging materials. All returned goods are to be shipped to Terra Universal, freight 

prepaid at customer’s expense. See Terra’s “Policy and Procedure for Returned Goods.”

 

 

Thank you for ordering from 

Terra Universal! 

Содержание 2700-12B

Страница 1: ... Guide Document No 1800 47 Nitrogen Generator Copyright 2017 Terra Universal Inc All rights reserved Revised June 2017 Terra Universal Inc TerraUniversal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 ...

Страница 2: ...er impurities in the incoming air line and ensuring a long service life Oil and moisture condensation from the prefilter and coalescing filters exits the system through a 1 4 slip fit connector that can be directed to an in house drain Proprietary Notice This manual pertains to proprietary devices manufactured by Terra Universal Inc Neither this document nor any portion of it may be reproduced in ...

Страница 3: ...mbrane Flow and purity are determined by adjusting either the pressure regulator or flowmeter If consistent outlet pressure is required set the pressure regulator at the desired level and then adjust the flowmeter to achieve the desired flow at your selected pressure The lower the flow rate at any pressure level the higher the product purity The higher the pressure at any flow rate the higher the ...

Страница 4: ...be monitored monthly Under continuous use at 100 PSI filters will operate for approximately two years 20 000 hours Replacing Filter Elements 1 Open the front housing panel of the Nitrogen Generator to expose the filters see Figure 1 2 Rotate the self locking bayonet head 1 8 turn counterclockwise to release it from the bowl see Figure 2 3 Pull the filter element to release it from the head Remove ...

Страница 5: ...ersal com 800 S Raymond Ave Fullerton CA 92831 TEL 714 578 6000 FAX 714 578 6020 5 5 0Specifications and Performance Data Model Dimensions Weight uncrated Flowmeter Range 2700 09 24 W x 14 D x 68 25 H 157 lbs 0 400 SCFH 2700 11 24 W x 12 D x 49 25 H 96 lbs 0 100 SCFH 2700 12 20 W x 12 D x 35 25 H 58 lbs 0 20 SCFH Includes polypropylene leveling feet excludes other hardware ...

Страница 6: ...ber filter beds coalesce and remove water droplets Remaining oil content 1 ppm by weight Includes slide indicator to indicate need for filter change liquid level indicator and internal drain ISO 8573 1 Quality Class Solids Class 2 Oil Content Class 4 Coalescing Filter Absolute filtration of 0 01µm particles 99 999 oil removal efficiency Includes slide indicator to indicate need for filter change l...

Страница 7: ... 24 90 psi 326 465 598 871 89 127 164 238 8 11 14 21 Typical Nitrogen Product Flow Rates Nm3 h SCFH flow at purity 13 8 barg 200 PSI and 45 C 113 F Model Purity Level 95 96 97 98 99 99 5 99 9 2700 09 65 55 45 36 26 20 11 2461 2084 1715 1350 970 745 407 2700 11 18 15 12 10 7 5 3 673 570 468 369 266 205 110 2700 12 1 5 1 3 1 1 0 8 0 6 0 5 0 3 59 49 41 32 23 18 10 Air Feed Requirements Nm3 h SCFH flo...

Страница 8: ...tely For Terra s Policy and Procedures for Returning Goods see Terra s Internet site www TerraUniversal com Generally customers can improve the chance of collecting on a freight claim by following these procedures 1 formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition 2 notifying the carrier upon discovery of concealed damage ...

Отзывы: