In case of installation of thick-walled metal, ceramic, asbestos-cement or other chimney stack of
greater weight it is necessary to unload the stove from its weight.
ATTENTION! The manufacturer shall not be responsible for the influence of external
factors on the reduction of natural draught in the stove pipe.
ATTENTION! It is prohibited to use chimney stacks with galvanic coating.
ATTENTION! Do not use pipes from different manufacturers in the stove pipe.
ATTENTION! To avoid the smoke blowing into the heated room all the places of chimney
stack units connection against each other and the stove it is necessary to compact with
high-temperature sealant (not less than 1000°С) providing the air-tightness of the pipe
junctions.
ATTENTION! The junction of stove pipe units in overlaps and fire block is prohibited.
ATTENTION! The section of chimney stack located in the zone of sub-zero temperatures
shall be obligatory heat insulated by non-combustible material, withstanding
temperatures not less than +400 °С.
The ideal solution for chimney stack – is the installation of ready-made pipe units with heat insulation
of ―sandwich‖ type of «Termofor» trademark.
In case of connection of the stove to fixed built-in stove pipe or in other cases it is not recommended
to deflect the axis of chimney stack from the vertical line for more than 45°.
ATTENTION! sauna stove and chimney stack assembly shall be carried out by qualified
workers from the specialized construction and installation company in compliance with
the requirements of SNIP 41-01-2003 (construction norms and rules) or in compliance
with technical norms of the country where the stove will be used.
ATTENTION! It is strictly prohibited to make dismountable the connections of the stove
with the stove pipe or other structural elements of the room.
ATTENTION! In case of fire in the stove pipe shut the dampers of air supply into the fire
chamber, leave the room and immediately call the firemen.
In case of fire in the stove pipe it is necessary to have a clear scheme of actions that shall be elaborated
by consulting the specialist. After the fire in the stove pipe will die down, the stove pipe shall be cleaned
and checked for the destructions. Make sure that there are no flammables around the stove pipe.
8.8. Stoves with heat exchange unit
Stoves with heat exchange unit help to locate the tank for hot water outside the steam room and install
it in wash room. «Termofor» heat exchange units are produced in two variants:
1) heat exchange unit of «samovar» type installed at the outlet nozzle of the stove pipe (do not
supplied as part of package);
2) built-in heat exchange unit, installed at the wall of fire chamber inside the stove (supplied with the
stove of corresponding model);