![Termofor Angara 2012 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/termofor/angara-2012/angara-2012_operation-manual_1089240013.webp)
13
It is recommended to install adjustable latches (7) in air inlet and exhaust outlet for possibility to
control air exchange.
ATTENTION! It is necessary to provide constant inflow of fresh air into the room where
the stove is operating. The breach of the condition may lead to unstable operation of the
stove and appearance of dangerous situations such as poisoning with carbon monoxide,
fire breaking-out.
8.6. Stove assembly
ATTENTION! All the stove assembly and stones setting into the stones section works shall
be carried out only after total cooling off of the stove.
ATTENTION! The stove is heavy. Make sure that you have the possibilities and equipment
for its moving.
ATTENTION! It is prohibited to install the stove in the places where the stove will create
obstacles for people moving during evacuation.
ATTENTION! It is necessary to carry out the installation of smoke sensors and gas
detectors in the rooms where the stove is installed.
Mount the stove to the specially prepared place. Make sure that the stove is assembled and installed
correctly.
Provided after reading this manual you still have any doubts concerning the stove correct installation
you should consult the stove assembly specialist who is aware of all the aspects of safe and correct
installation of stoves.
A scheme of installation of the stove is presented in figure 6. Distance from the door of the combustor
till the wall opposite will be at least 1250 mm. Distance between the top of the stove and an unguarded
ceiling will be at least 1200 mm.
Distance between an external surface of the stove, flue and wall will be at least 500 mm, for
constructions of inflammable materials will be 380 mm, for constructions of inflammable and combustible
with difficulty materials which are protected by a metal plate on an asbestos paper with thickness 10 mm or
with plaster on expanded metal with thickness 25 mm.
Do not install the stove into the niche in a wall or into the fire place.
Distance from the side of a fuel channel till a wall shall be at least 30 mm. If thickness of a wall is 125
mm then a door of a combustor will have the most correct position.
Wall opening for fuel channel from the level of support feet shall have the following dimensions
(height × width):
for «Angara 2012 2011» models — 480×270 mm.
for «Angara 2012 2011 Vitra» models — 545×410 mm.