8. TECHNICAL DATA
QUALITY CERTIFICATION
Pursuant
to
BkM-IpM
Decree
A2/1984
(III.10.),
we
hereby
declare that the appliance complies
with
the
following
technical
characteristics:
Applicable
electric
shock
protection:
electric
shock
protection
class
I.
Can
be
connected to electricity network
supplied with protective earthing as
defined in IEC 60364. Main
regulations
pertaining
to
the
product: EN 60335-1, EN 60335-2-
21.
Storage and transporting criteria:
EN 60721-3
TÍPUS
TREND
30 N
TREND
50 N
TREND
80 N
TREND
100 N
TREND
120 N
TREND
150 N
TREND
200 N
Description
Unvented water heater
Placement direction
Wall mounted
Volume (l)
30
50
80
100
120
150
200
Voltage (V)
230~
Heating Power (W)
1600
1600
1800
1800
1800
2400
2400
Current (A)
7
7
7,9
7,9
10,5
10,5
10,5
Heat-up time from 15
ºC to 65 ºC (h)
1,16
1,2
1,9
2,8
4,2
5,2
5,2
Stand-by energie at
65ºC (Wh/24h)
0,83
0,933
1,42
1,51
1,91
2,38
2,75
Tube connections
G1/2
Net mass(kg)
16,2
19,7
25,0
28,5
31,9
39,0
48,5
Nominal operation
preasurre (MPa)
0,6
Highest open
preasure point of
safety valve (MPa)
0,7
Built in safety
elements:
Combined thermostat
Safety pressure valve
Other safety
elements:
Active anode corrosion protection