P L
E N R U D E
If the heating element is installed in a radiator being a part of heating system the lowest
valve must be closed (side connection to heating system), or thermostatic valve in case
of bottom connection. Keep the other valve open to enable the water which increase its
volume while being heating up to flow out of a radiator.
ATTENTION !
In case of electrical radiator (not connected to heating system), the radiator can be filled
with water or oil. It is important to comply with radiator’s producer requirements
concerning the installation and correct operation. It’s very important to take into
consideration the heating medium thermal expansion. Filling the radiator with to much
liquid volume leads to exceed maximum pressure limits.
ATTENTION!
V. IMPORTANT SAFEGUARDS
1.
The heating element must be mounted and connected according to producer's requirements
written in the manual.
2
. For the sake of burn risk protect the radiator against children and home pets.
3.
Be careful, do not touch hot elements of device by any part of your body or by supply cord.
4.
Manufacturer
is not responsible for any damages to your heath, body or property if any changes
were made by the user himself.
5.
Do not turn on the heater longer than for 3 seconds in the open air.
6.
The device is dedicated for household and similar usage.
7.
Do not let the heater can be pour with water.
VI. OPERATING INSTRUCTIONS
1.
Button turns on and off the heater
2.
Buttons and are used to set the temperature. Button increase and button decrease set
temperature.
INDICATING OF OPERATING CONDITIONS
Leds display
Operating condition / Heater’s temperature
Long flashes, short breaks
Heater works, it means that set temperature is higher then
current. Fixed light leds indicate current lower temperature.
Flashing leds indicate higer set temperature.
Heater keeps set temperature, it means set temperature
is reached. Heater adjust the power itself just to keep set
temperature. Fixed light leds show set current temperature
Heater cools down, it means set temperature is higher then
currnent. Fixed light leds indicate lower set temperature.
Flashing leds indicate higher current temperature.
Fixed light
Short flashes, long breaks
heating element control box in a right position at the same time (draw. 14).
4.
Fill the radiator with liquid. Remember to open the highest valve if the heater is installed in dual fuel
version. Remember of liquid expansion in case of electrical version.
5.
After
checking if the connection are tight and insulated the device is ready to use.
10