TELELIFT 3713 SX
SCHEDULED MAINTENANCE INSPECTIONS
0
4
0
Document 57.4402.9200 - 1
st
Edition 10/2006
INDEX
Checking the limit switches of the outriggers
(at every use)
To check the limit switches of the outriggers:
• Lower the outriggers to the ground and attempt to
engage a gear.
If the gear can be engaged, contact the TEREXLIFT
Technical Assistance Service.
Proceed on one outrigger at a time.
• With the outriggers up, light
A
on the load limiter
panel must be off; with the outriggers down to the
ground, the same light must be on. Should it not
be the case, contact the TEREXLIFT Technical
Assistance Service.
If a limit switch is faulty or a lever is deformed,
immediately replace the part.
Checking the sensor on the boom
(at every use)
• Raise the boom beyond the horizontal and ensure the
sway control and the outrigger control are blocked.
Should that not be the case, contact the TEREXLIFT
Technical Assistance Service.
A
C
B