Tech-Tip 93
21
Released: 6/19/2019
Tech Tips
The Single Stick Qualification and Periodic
readings are shown below.
For a Single Stick Control AC Qualification and
Periodic/ Maintenance test the reading should
be no higher than 400 µA for 3 minutes at 40
KV.
µA=Microamp
Step 19
Once testing is complete lower the platform to
the ground mount position. Remove the spring
from the control handle and current meter return
from the upper control valve fitting.
Step 20
Store the unit and raise the outriggers. Remove
any barriers around the unit and drive the unit off
the pads and out of the dielectric test area.