September 2016
Service and Repair Manual
Platform Controls
Part No. 1268528
Z-40/23N, Z-40/23N RJ
17
How to Adj ust the Functi on R amp U p Time Setti ng
How to Adjust the Function Ramp
Up Time Setting
The ramp up time setting of a function controls the
time at which it takes for the function to reach
maximum output, when moved out of the neutral
position. The ramp up time of a function can be
changed to compensate for hydraulic pump wear to
maintain peak performance from the machine.
Note: Begin this procedure with the rotary speed
control at the platform turned fully in the clockwise
direction.
1 Turn the key switch to platform control.
2 Pull out the red Emergency Stop button to the
'ON' position at both the ground and platform
controls.
3 Do not press down on the foot switch.
4 Move and hold the drive enable toggle switch
in the right direction while holding the steer
rocker switch in the right direction.
5 When the display leaves SYSTEM READY
mode, release the drive enable toggle switch
and the steer rocker switch.
Result: The display will show FAULTS.
6 Momentarily activate the steer rocker switch in
the right direction until SETTINGS is shown on
the display.
7 Momentarily activate the drive enable toggle
switch in the right direction until VALVE AND
PUMP SETTINGS is shown on the display.
8 Momentarily activate the drive enable toggle
switch in the right direction until THRESHOLD
is shown on the display.
9 Momentarily activate the steer rocker switch in
the right direction until RAMP UP TIME is
shown on the display.
10 Momentarily activate the drive enable toggle
switch in the right direction to enter RAMP UP
TIME calibration mode.
11 Press down on the foot switch and
momentarily activate the function to be
corrected.
Result: The display will show the function,
direction and milliamps.
12 Press down on the foot switch, start a timer
and activate the same function in the same
direction.
Note how long it takes the function to reach
maximum speed. This is the ramp up time.
13 Compare the function ramp up time with the
table on the next page and determine whether
the ramp up time needs to increase or
decrease.
Содержание Genie Z-40/23N
Страница 20: ...Service and Repair Manual September 2016 Specifications 10 Z 40 23N Z 40 23N RJ Part No 1268528 ...
Страница 63: ...September 2016 Service and Repair Manual Manifolds Part No 1268528 Z 40 23N Z 40 23N RJ 53 ...
Страница 103: ...September 2016 Service and Repair Manual Power Cable Diagram Part No 1268528 Z 40 23N Z 40 23N RJ 93 ...
Страница 110: ...Service and Repair Manual September 2016 100 Z 40 23N Z 40 23N RJ Part No 1268528 This page intentionally left blank ...
Страница 111: ...September 2016 Service and Repair Manual 101 Electrical Schematic Chassis ...
Страница 112: ...Service and Repair Manual September 2016 102 Z 40 23N Z 40 23N RJ Part No 1268528 Electrical Schematic Chassis ...
Страница 113: ...September 2016 Service and Repair Manual Part No 1268528 Z 40 23N Z 40 23N RJ 103 Electrical Schematic Ground Controls ...
Страница 114: ...Service and Repair Manual September 2016 104 Electrical Schematic Ground Controls ...
Страница 115: ...September 2016 Service and Repair Manual 105 Electrical Schematic Platform Controls ...
Страница 117: ...September 2016 Service and Repair Manual Part No 1268528 Z 40 23N Z 40 23N RJ 107 Ground Control Box Wiring Diagram ...
Страница 118: ...Service and Repair Manual September 2016 108 Ground Control Box Wiring Diagram ...
Страница 119: ...September 2016 Service and Repair Manual 109 Platform Control Box Wiring Diagram ...
Страница 120: ...Service and Repair Manual September 2016 110 Z 40 23N Z 40 23N RJ Part No 1268528 Platform Control Box Wiring Diagram ...
Страница 122: ...Service and Repair Manual September 2016 112 Platform Control Box Wiring Diagram Options ...
Страница 123: ...September 2016 Service and Repair Manual 113 Hydraulic Schematic ...
Страница 125: ......