Page
D-8
Document 57.0007.0200 - 01/2006
MAINTENANCE
Handler with telescopic boom
GTH-4013
■
D-3.2
GREASING
ATTENTION
Before injecting grease into the greasers, thoroughly
clean them to avoid that mud, dust or other matters
can mix with the lubricant and reduce or annihilate
the lubrication effect.
Remove any old grease with a degreaser from the
telescopes before smearing them with new grease.
Regularly grease the machine to grant it efficient
conditions and a long life.
By means of a pump, inject grease into the special
greasers.
As the fresh grease comes out, stop the operation.
The greasing points are shown in the following figures:
-
the symbol
represents the points to be greased
by a pump
-
the symbol
represents the points to be
greased by a brush
SERVICE INTERVAL
Running-in ____________________________
None
Ordinary ____________________
Every
10
hours
ATTENTION
Use only PTFE INTERFLON FIN GREASE LS 2 to
lubricate the sliding parts of the telescopic section.
Observe the following schedule:
•
After the first 50 operating hours (1 week)
•
After the first 250 operating hours (1 month)
•
Every 1000 operating hours (6 months)
Remove any old grease from the boom and smear
the sliding area of the blocks with a thin coat of
grease.