4-20
GTH-1256
Part No. 1272856
September 2016
Section 4 • Fault Codes
3248
1
Physical range check low for exhaust gas temperature particulate
fi
lter downstream; warning
1188
11
Wastegate actuator; internal error
1188
11
Wastegate actuator; EOL calibration not performed correctly
1188
13
Wastegate actuator calibration deviation too large, recalibration required
1188
2
Wastegate; status message from ECU missing
1188
7
Wastegate actuator; blocked
1188
11
Wastegate actuator; over temperature (> 145°C)
1188
11
Wastegate actuator; over temperature (> 135°C)
1188
11
Wastegate actuator; operating voltage error
524011
0
Zerofuel calibration injector 7 (in
fi
ring order); maximum value exceeded
524012
0
Zerofuel calibration injector 8 (in
fi
ring order); maximum value exceeded
524011
1
Zerofuel calibration injector 7 (in
fi
ring order); minimum value exceeded
524012
1
Zerofuel calibration injector 8 (in
fi
ring order); minimum value exceeded
524028
2
CAN message PROEGRActr; plausibility error
524029
2
Timeout Error of CAN-Receive-Frame ComEGRActr -exhaust gas recirculation positioner
524034
5
Disc Separator; open load
524034
12
Disc Separator; powerstage over temperature
524034
3
Disc separator; short circuit to battery
524034
4
Disc separator; short circuit to ground
524030
7
EGR actuator; internal error
524031
13
EGR actuator; calibration error
524032
2
EGR actuator; status message "EGRCust" is missing
524033
7
EGR actuator; due to overload in Save Mode
2621
5
Flush valve burner (EPV DPF-System); open load
2621
12
Flush valve burner (EPV DPF-System); powerstage over temperature
2621
3
Flush valve burner (EPV DPF-System); short circuit to battery
2621
4
Flush valve burner (EPV DPF-System); short circuit to ground
175
0
High customer oil temperature; warning threshold exceeded
175
0
High customer oil temperature; shut off threshold exceeded
3711
12
Regeneration temperature (PFltRgn LigtOff) not reached; regeneration aborted
524055
4
Spark Plug Control Unit (SPCU); short circuit to ground
523960
0
High exhaust gas temperature EGR cooler downstream; warning threshold exceeded
523960
1
High exhaust gas temperature EGR cooler downstream; shut off threshold exceeded
1180
0
Turbocharger Wastegate CAN feedback; warning threshold exceeded
1180
1
Turbocharger Wastegate CAN feedback; shut off threshold exceeded
1180
0
Exhaust gas temperature upstream turbine; warning threshold exceeded
FAULT CODES
Содержание Genie GTH-1256
Страница 5: ...September 2016 Part No 1272856 GTH 1256 v INTRODUCTION Serial Number legend 6 5 5...
Страница 6: ...vi GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 12: ...xii GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 24: ...2 12 GTH 1256 Part No 1272856 September 2016 Section 2 Specifications This page intentionally left blank...
Страница 132: ...5 20 GTH 1256 Part No 1272856 September 2016 Section 5 Schematics This page intentionally left blank...
Страница 133: ...September 2016 Section 5 Schematics 5 21 5 22 Hydraulic Schematic Deutz Engine Deutz engine Sheet 1 of 2...
Страница 136: ......