4-12
GTH-1256
Part No. 1272856
September 2016
Section 4 • Fault Codes
3241
0
Sensor SCR catalyst upstream temperature too high; plausibility error
3241
1
Sensor SCR catalyst upstream temperature too low; plausibility error
3361
7
AdBlue dosing valve blocked (SCR)
523720
2
Sensor urea supply module heater temperature; plausibility error (normal condition)
523720
2
Sensor urea supply module heater temperature; plausibility error (cold start condition)
523721
2
Sesnor urea supply module temperature; plausibility error (normal condition)
523721
2
Sensor urea supply module temperature; plausibility error (cold start condition)
523981
11
Urea-tank without heating function (heating phase)
523330
14
Immobilizer status; fuel blocked
523720
8
Urea supply module heater temperature; duty cycle in failure range
523720
8
Urea supply module heater temperature; duty cycle in invalid range
523721
11
Urea supply module temperature measurement not available
523722
8
Urea supply module PWM signal; period outside valid range
523722
8
Detect faulty PWM signal from Supply Modul
523721
8
Urea supply module temperature; duty cycle in failure range
523721
8
Urea supply module temperature; duty cycle in invalid range
29
3
Handthrottle idle validation switch; short circuit to battery
91
8
Accelerator pedal duty cycle PWM signal; signal range check high
91
8
Acceleration pedal cycle duration PWM signal; signal range check high
91
3
Sensor error accelerator pedal; signal range check high
29
3
Sesnor error handthrottle; signal range check high
29
4
Handthrottle idle validation switch; short circuit to ground
91
8
Accelerator pedal dutycycle PWM signal; signal range check low
91
8
Acceleration pedal cycle duration PWM signal; signal range check low
91
4
Sensor error accelerator pedal; signal range check low
29
4
Sensor error handthrottle sensor; signal range check low
523921
3
Sensor error burner temperature; signal range check high
3532
3
Sensor error urea tank level; signal range check high
523921
4
Sensor error burner temperature; signal range check low
3532
4
Sensor error urea tank level; signal range check low
1079
13
Sensor supply voltage monitor 1 error (ECU)
1080
13
Sensor supply voltage monitor 2 error (ECU)
523601
13
Sensor supply voltage monitor 3 error (ECU)
677
3
Starter relay high side; short circuit to battery
677
4
Starter relay high side; short circuit to ground
677
5
Starter relay; no load error
FAULT CODES
Содержание Genie GTH-1256
Страница 5: ...September 2016 Part No 1272856 GTH 1256 v INTRODUCTION Serial Number legend 6 5 5...
Страница 6: ...vi GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 12: ...xii GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 24: ...2 12 GTH 1256 Part No 1272856 September 2016 Section 2 Specifications This page intentionally left blank...
Страница 132: ...5 20 GTH 1256 Part No 1272856 September 2016 Section 5 Schematics This page intentionally left blank...
Страница 133: ...September 2016 Section 5 Schematics 5 21 5 22 Hydraulic Schematic Deutz Engine Deutz engine Sheet 1 of 2...
Страница 136: ......