4-34
GTH-1256
Part No. 1272856
September 2016
Section 4 • Fault Codes
523720
8
Urea supply module heater temperature; duty cycle in invalid range
523721
2
Sesnor urea supply module temperature; plausibility error (normal condition)
523721
2
Sensor urea supply module temperature; plausibility error (cold start condition)
523721
8
Urea supply module temperature; duty cycle in failure range
523721
8
Urea supply module temperature; duty cycle in invalid range
523721
11
Urea supply module temperature measurement not available
523722
8
Urea supply module PWM signal; period outside valid range
523722
8
Detect faulty PWM signal from Supply Modul
523723
11
Detection of AdBlue
fi
lled SCR system in Init-State
523766
9
Timeout Error of CAN-Receive-Frame Active TSC1AE
523767
9
Timeout Error of CAN-Receive-Frame Passive TSC1AE
523768
9
Timeout Error of CAN-Receive-Frame Active TSC1AR
523769
9
Timeout Error of CAN-Receive-Frame Passive TSC1AR
523770
9
Timeout Error of CAN-Receive-Frame Passive TSC1DE
523776
9
Timeout Error of CAN-Receive-Frame TSC1TE -active
523777
9
Passive Timeout Error of CAN-Receive-Frame TSC1TE; Setpoint
523778
9
Active Timeout Errorof CAN-Receive-Frame TSC1TR
523779
9
Passive Timeout Error of CAN-Receive-Frame TSC1TR
523788
0
CAN-Transmit-Frame ComTrbChActr "BusOff-Satus"; Wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr disable error; wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr plausibility error; wastegate
523788
0
Timeout Error of CAN-Transmit-Frame ComTrbChActr; Wastegate
523788
12
Timeout Error of CAN-Transmit-Frame TrbCH; Status Wastegate
523793
9
Timeout Error of CAN-Receive-Frame UAA10; AGS sensor service message
523794
9
Timeout Error of CAN-Receive-Frame UAA11; AGS sensor data
523803
9
Timeout Error of CAN-Receive-Frame RxEngPres; Status burner airpump
523867
12
Timeout Error of CAN-Transmit-Frame UAA1 on CAN 2; Burner Air Pump Control
523895
13
Check of missing injector adjustment value programming (IMA) injector 1 (in
fi
ring order)
523896
13
check of missing injector adjustment value programming (IMA) injector 2 (in
fi
ring order)
523897
13
check of missing injector adjustment value programming (IMA) injector 3 (in
fi
ring order)
523898
13
check of missing injector adjustment value programming (IMA) injector 4 (in
fi
ring order)
523899
13
check of missing injector adjustment value programming (IMA) injector 5 (in
fi
ring order)
523900
13
check of missing injector adjustment value programming (IMA) injector 6 (in
fi
ring order)
523910
0
Air Pump; powerstage over temperature
523910
0
Air Pump; operating voltage error
523910
6
Air Pump; over current
FAULT CODES
Содержание Genie GTH-1256
Страница 5: ...September 2016 Part No 1272856 GTH 1256 v INTRODUCTION Serial Number legend 6 5 5...
Страница 6: ...vi GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 12: ...xii GTH 1256 Part No 1272856 September 2016 This page intentionally left blank...
Страница 24: ...2 12 GTH 1256 Part No 1272856 September 2016 Section 2 Specifications This page intentionally left blank...
Страница 132: ...5 20 GTH 1256 Part No 1272856 September 2016 Section 5 Schematics This page intentionally left blank...
Страница 133: ...September 2016 Section 5 Schematics 5 21 5 22 Hydraulic Schematic Deutz Engine Deutz engine Sheet 1 of 2...
Страница 136: ......