Manifolds
60
GS
™
-2669 DC • GS
™
-3369 DC • GS
™
-4069 DC
Part No. 1306585GT
6-4 Valve Coils
6-4
Valve Coils
How to Test a Coil
A properly functioning coil provides an
electromagnetic force which operates the solenoid
valve. Critical to normal operation is continuity
within the coil. Zero resistance or infinite
resistance indicates the coil has failed.
Since coil resistance is sensitive to temperature,
resistance values outside specification can
produce erratic operation. When coil resistance
decreases below specification, amperage
increases. As resistance rises above specification,
voltage increases.
While valves may operate when coil resistance is
outside specification, maintaining coils within
specification will help ensure proper valve function
over a wide range of operating temperatures.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
Note: If the machine has been in operation, allow
the coil to cool at least 3 hours before performing
this test.
1 Tag and disconnect the wiring from the coil to
be tested.
2 Test the coil resistance using a multimeter set
to resistance (
Ω
). Refer to the Valve Coil
Resistance Specification table.
Result: If the resistance is not within the
adjusted specification, plus or minus 10%,
replace the coil.
Valve Coil Resistance
Specification
Note: The following coil resistance specifications
are at an ambient temperature of 68°F / 20°C. As
valve coil resistance is sensitive to changes in air
temperature, the coil resistance will typically
increase or decrease by 4% for each 18°F / 20°C
that your air temperature increases or decreases
from 68°F / 20°C.
Description
Specification
Solenoid valve, 2 position 2 way
24V DC with diode
(schematic items CA, CB, CC, CD,
CE, CF)
25
Ω
Solenoid valve, 2 position 3 way
24V DC with diode
(schematic items BA, FB, FF, FO, FP,
FR, )
35
Ω
Solenoid valve, 3 position 5 way
24V DC with diode (schematic item
FL)
35
Ω
Содержание Genie GS-2669 DC
Страница 62: ...Service and Repair Manual May 2021 Manifolds 50 GS 2669 DC GS 3369 DC GS 4069 DC Part No 1306585GT ...
Страница 135: ...May 2021 Service and Repair Manual 123 use Ground and Platform Control Boxes Fuse Box Layout All Models ...
Страница 138: ...Service and Repair Manual May 2021 126 Ground Control Box Layout ...
Страница 140: ...Service and Repair Manual May 2021 128 Platform Control Box Layout ...
Страница 141: ...May 2021 Service and Repair Manual 129 Electrical Schematics Electrical Schematic ...
Страница 144: ...Service and Repair Manual May 2021 132 Electrical Schematic ...
Страница 145: ...May 2021 Service and Repair Manual 133 Hydraulic Schematics Hydraulic Schematic ...
Страница 147: ......