![Terex Genie GS-2669 DC Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/terex/genie-gs-2669-dc/genie-gs-2669-dc_service-and-repair-manual_1088846108.webp)
Service and Repair Manual
May 2021
Fault Codes
96
GS
™
-2669 DC • GS
™
-3369 DC • GS
™
-4069 DC
Part No. 1306585GT
Error Source
Error Type
Condition
Solution
ID
Name
ID Name
213 Height sensor
(Safety)
12 Value too high
Output higher than
normal.
• Check wiring
• Check 5V supply voltage
• Shorted too high
• Replace sensor
15 Value too low
Output lower than
normal.
• Check wiring
• Check 5V supply voltage
• Check ground
• Open or short circuit
• Replace sensor
16 Value at 0 V
Output at 0 volts.
• Check wiring
• Open circuit.
• Replace sensor
• Replace SCON
23 Too high
Outputs higher than
calibration point.
• Check height sensor for loose
or missing fasteners.
• Calibrate Sensor
24 Too low
Outputs lower than
calibration point.
• Check height sensor for loose
or missing fasteners
• Calibrate Sensor
Содержание Genie GS-2669 DC
Страница 62: ...Service and Repair Manual May 2021 Manifolds 50 GS 2669 DC GS 3369 DC GS 4069 DC Part No 1306585GT ...
Страница 135: ...May 2021 Service and Repair Manual 123 use Ground and Platform Control Boxes Fuse Box Layout All Models ...
Страница 138: ...Service and Repair Manual May 2021 126 Ground Control Box Layout ...
Страница 140: ...Service and Repair Manual May 2021 128 Platform Control Box Layout ...
Страница 141: ...May 2021 Service and Repair Manual 129 Electrical Schematics Electrical Schematic ...
Страница 144: ...Service and Repair Manual May 2021 132 Electrical Schematic ...
Страница 145: ...May 2021 Service and Repair Manual 133 Hydraulic Schematics Hydraulic Schematic ...
Страница 147: ......