![Terex Genie GS-2669 DC Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/terex/genie-gs-2669-dc/genie-gs-2669-dc_service-and-repair-manual_1088846103.webp)
May 2021
Service and Repair Manual
Fault Codes
Part No. 1306585GT
GS
™
-2669 DC • GS
™
-3369 DC • GS
™
-4069 DC
91
ID
System Ready
LED Condition
Result
Solution
32
PLATFORM
START SW
FAULT
Red Engine start button fault at
platform controls.
Engine will not start. Troubleshoot button OR
replace printed circuit board
at platform controls.
33
LEFT FRONT
OUTRIG SW FLT
Red Left front outrigger enable
button fault at platform
controls.
Outriggers disabled. Troubleshoot button OR
replace printed circuit board
at platform controls.
34
RIGHT FRONT
OUTRIG SW FLT
Red Right front outrigger enable
button fault at platform
controls.
Outriggers disabled. Troubleshoot button OR
replace printed circuit board
at platform controls.
35
LEFT REAR
OUTRIG SW FLT
Red Left rear outrigger enable
button fault at platform
controls.
Outriggers disabled. Troubleshoot button OR
replace printed circuit board
at platform controls.
36
RIGHT REAR
OUTRIG SW FLT
Red Right rear outrigger enable
button fault at platform
controls.
Outriggers disabled. Troubleshoot button OR
replace printed circuit board
at platform controls.
37
AUTO LEVEL
SWITCH FAULT
Red Outrigger auto level enable
button fault at platform
controls.
Outriggers disabled. Troubleshoot button OR
replace printed circuit board
at platform controls.
3812 OSCILLATE
LIMIT SWITCHES
Red Value to high. Voltage
above 3000 mV.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches.
3815 OSCILLATE
LIMIT SWITCHES
Red Value to low. Voltage below
1000 mV.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches.
3819 OSCILLATE
LIMIT SWITCHES
Red Voltage out of range.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches.
3821 OSCILLATE
LIMIT SWITCHES
Red Voltage inconsistent.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches.
4021 OSCILLATE
OUTPUT
Red Both oscillate valve outputs
are on at the same time
while elevated.
Flashing or Motion Beacon
option is set to
on
and it is
not installed on the
machine.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches or replace ECU.
Set the option to
off
if not
installed on the machine.
4022 OSCILLATE
OUTPUT
Red Oscillate valve output is
active for more than
4 seconds.
Elevated drive and
platform up disabled.
Troubleshoot oscillate limit
switches or replace ECU.
49
DRIVE COIL 1
FAULT
Red Drive coil 1 (Y1) fault.
High speed drive
function will not
operate.
Troubleshoot coil OR wiring.
Содержание Genie GS-2669 DC
Страница 62: ...Service and Repair Manual May 2021 Manifolds 50 GS 2669 DC GS 3369 DC GS 4069 DC Part No 1306585GT ...
Страница 135: ...May 2021 Service and Repair Manual 123 use Ground and Platform Control Boxes Fuse Box Layout All Models ...
Страница 138: ...Service and Repair Manual May 2021 126 Ground Control Box Layout ...
Страница 140: ...Service and Repair Manual May 2021 128 Platform Control Box Layout ...
Страница 141: ...May 2021 Service and Repair Manual 129 Electrical Schematics Electrical Schematic ...
Страница 144: ...Service and Repair Manual May 2021 132 Electrical Schematic ...
Страница 145: ...May 2021 Service and Repair Manual 133 Hydraulic Schematics Hydraulic Schematic ...
Страница 147: ......