![Terex 3B6 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/terex/3b6/3b6_troubleshooting-manual_1088772023.webp)
+ GND
23
Verify 5Volts between
+V and –V (MS1)
on cable reel board
FALSE
TRUE
Verify the
Potentiometers
(**)
Verify on the Main PC board
5Volts between
7(+) and 8(GND)
Cable brake down.
Check the
cable-reel cable
Disconnect wires
7 and 8 from the
Main pc board and
Check for 5Vdc
TRUE
FALSE
TRUE
FALSE
Probably the cable is
in short circuit.
Check cable
Main pc board
Is faulty.
Replace it with
a new one (*)
CABLE REEL POWER SUPPLY VERIFYING
CABLE REEL POWER SUPPLY VERIFYING
(*) REFER ALSO TO EPROM and EEPROM MEMORIES REPLACEMENT - page 32
(**) REFER TO pages 24
+V -V