![Terex 3B6 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/terex/3b6/3b6_troubleshooting-manual_1088772013.webp)
m
m
13
CONTROL PANEL DESCRIPTION
CONTROL PANEL DESCRIPTION
1
Working data display;
5
GREEN Button/lamp : if pressed, it allows the operator to scroll the pages
lit = safety
6
AMBER Button/lamp :The lamp lit indicates that the load has reached the pre-alarm
condition. Pressing the button, the buzzer will stop.
7
RED Button/lamp :The lamp lit indicates that the load has reached the maximum
load allowed and the shut off has been performed;
The flashing light indicates that the machine is in shut down
procedures and the by pass key is activated.
The button can also used to confirm a selection.
8
Operating mode selection button: press to increase operating mode value;
9
Operating mode selection button: press to decrease operating mode value;
10
Rope number ( tackle ) selection key: press as many times as necessary to obtain the
required value in order to achieve a correct load reading;
11
Key to exclude the manoeuvre block
Note : The function of the unstable key with return spring consists on disable the
automatic alarm function of the safety system.
Only the authorised staff can use the key to by-pass the safety system. In case of
improper use, the safety equipment and the crane manufacturer are relieved of any
responsibility.
11
Buzzer ( positioned on the rear panel ) :
Intermittent beeping = pre alarm condition;
Continuous beeping = alarm condition ( shut off movements).
1
7
10
6
9
5
8
11
12