D2
14
13 BLK
POS
RIBBON CABLE CONNECTOR P6
CONTROL BOARD
R14 - Tank Level Switches
STANDOFF 2
M1B
1 RED
NEG
TOUCH
PANEL
50 RED
S1
M1A
D1
KEYSWITCH
RIBBON CABLE
-
50 RED
2
2
14
MAIN CONTACTOR
6
5
5
5
6
3
26
3
4
4
4
4
PIN J6-17
PIN J6-5
PIN J6-24
PIN J6-18
PIN J6-13
14
1 RED
POST J11
POST J7
Wiring Color Codes
(Unless otherwise marked)
0
1
2
3
4
5
6
7
8
9
Tan
Pink
Brown
Orange
Yellow
Green
Blue
Purple
Gray
White
Right Most Digit
of Wire Number
Color of Wire
= Battery Negative
or Logic Ground
= Battery Positive
or Positive Output
CB1
5 A
CB2
15 A
+
F1
100 A
SW5
CONDITIONS:
Key ON, operator on seat
28
29
42
42
RECOVERY TANK
FULL SWITCH
LOGIC GROUND
42
PIN J6-20
PIN J6-35
PIN J6-8
SOLUTION TANK
LOW SWITCH
SW3
SW4
switch
tank full
tank empty switch OPEN switch CLOSED
indicator
x
x
Solution Tank Empty LED OFF
x
x
Solution Tank Empty LED ON
x
x
Recovery Tank Full LED ON
x
x
Recovery Tank Full LED OFF
Solution Tank
Recovery Tank
Tank Level Switches Logic Chart
Recovery Tank Full Switch
closes
when recovery tank is full
Solution Tank Low Switch
opens
when solution tank is low
Tank Level Switches are ALWAYS in the OPEN position with low or
empty tank
Tank Level Switches are ALWAYS in the CLOSED position with full tank
i
LEFT SIDE
DASH PANEL
1 RED
13 BLK
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
+
-
6 VDC
STANDOFF 1
SW1
CHARGER
INTERLOCK
FLYBACK PATH
TO CB2 PROTECTED
COMPONENTS
14
!
Be cautious when working
near Control Board -
Battery voltage is always
present, even with Key OFF
EMERGENCY STOP
SWITCH (E-STOP)
32