CIRCUIT BREAKERS / FUSES
The machine is equipped with two resettable circuit
breakers and two fuses to protect the machine from
damage. If a breaker should trip, determine the cause,
allow the motor to cool then reset the circuit breaker
button.
The circuit breakers and the fuses are located inside
the battery compartment near the hour meter (Figure
30). When replacing a blown fuse never substitute a
higher amp rated fuse than specified.
CIRCUIT BREAKERS:
5 A -- controller key switch input
15 A -- solution pump/solution solenoid/ brake/horn/
hour meter
(See page 30 for solution solenoid
reference)
FUSES:
100 A -- main (part no. 86379)
7.5 A -- solution pump (part no. 1016039)
100 A Fuse
5A
15A
7.5 A Fuse
7.5 A Fuse
FIG. 30
CHARGING BATTERIES
ATTENTION: To prolong the life of the batteries
only recharge the batteries if the machine was
used for a total of 30 minutes or more. Do not leave
batteries discharged for lengthy periods.
WARNING: Fire Or Explosion Hazard.
Batteries Emit Hydrogen Gas. Keep Sparks And
Open Flame Away. Keep Battery Compartment
Open When Charging.
FOR SAFETY: When servicing batteries, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
BATTERY CHARGER SPECIFICATIONS
S
CHARGER TYPE:
-- FOR WET (Lead acid) BATTERIES
S
OUTPUT VOLTAGE - 24 VOLTS
S
OUTPUT CURRENT - 30 AMPS
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
1. Park the machine on a flat, dry surface and turn the
key off. Make sure the area is well ventilated.
2. Tilt the seat forward for ventilation (Figure 39). Use
the seat stand to hold the seat up.
FIG. 39
3. Check the battery fluid level before charging (Figure
40). The fluid level should slightly cover the battery
plates. Add distilled water if low. DO NOT
OVERFILL. The fluid will expand and may overflow
when charging.
FOR SAFETY: When servicing batteries, wear
protective gloves and eye protection when
handling batteries and battery cables. Avoid
contact with battery acid.
Battery Plates
FIG. 40
4. Connect the charger’s AC power supply cord into a
properly grounded wall outlet.
(Page 1 of 11)
R14 1032129 REV.01 (12-06)
7