47/65
CHAPTER 11 – I-MOP VACUUM MOTOR REPLACEMENT
1.
WARNING!
Wear gloves when you touch electrical components to avoid ESD damage.
2. Remove the 4 SCREWS M4X12 CROSS HEAD and open the MOTOR UNIT TOP
3. Remove the 2 SCREWS EJOT DELTA PT 50X14 and extract the ASSY MAGNETIC VALVE
4. Remove the MAGNET TOP UNIT 40X20X10MM, the put a steel tool such as wrench there to hold the
vacuum unit to the brush unit
5. Unscrew the 8 SCREWS EJOT DELTA PT 50X14
6. Open the MOTOR UNIT COVER extracting the POWER CABLES 2 WIRES
7. Extract the VACUUM MOTOR GROUP
8. Unplug the DOMEL VACUUM CLEANER MOTOR of the POWER CABLES 3 WIRES with attention to
not extract the POWER CABLES2 WIRES from the VACUUM MOTOR SEALING SUPPORT
9. Replace the DOMEL VACUUM CLEANER MOTOR
47-1
47-2
47-3
47-4
47-5
47-6
47-7
Содержание i-team i-mop xxl
Страница 1: ...1 64 i mop xxl Service Manual Jan 2018 Warning read the instructions before using the machine...
Страница 10: ...10 64 7 Recovery tank 8 Left battery 9 Right battery 10 Transport wheels 11 Brush motors 9 7 8 10 11...
Страница 11: ...11 64 Internal view 1 Vacuum motor filter 2 Transparent plastic deflector 3 Vacuum hose 2 3 1...
Страница 53: ...53 65 2 14 Fasten 3pcs EJOT SCREW 50X14 to fix the COVER BRUSH MOTOR SCREW each side 53 1...
Страница 57: ...CHAPTER 16 ELECTRICAL SCHEME 57 65 57 1...
Страница 61: ...D if the reading is above 16V the battery is OK 61 65 61 1 61 2...
Страница 63: ...CHAPTER 19 REPAIR FLOW CHART 63 64 64 1 64 2...
Страница 64: ...64 64 65 1 Tennant Company PO Box 1452 Minneapolis MN 55440 Phone 1 800 553 8033 www tennantco com...