19/64
CHAPTER 6 – I-MOP MAGNETIC VALVE REPLACEMENT
INSTRUCTIONS
1.
WARNING!
Wear gloves when you touch electrical components to avoid ESD.
2. Remove the 4 SCREWS M4X12 CROSS HEAD and open the MOTOR UNIT TOP
3. Remove the 2 SCREWS EJOT DELTA PT 50X14 and extract the ASSY MAGNETIC VALVE
4. Unplug the PCB MAGNETIC VALVE & VAC MOTOR CONNECTION, the cables of the ASSY
MAGNETIC VALVE are the external ones. If needed remove the SCREW PARKER 2.9X16
5. Remove the VALVE COUPLINGS and the CHANNELS Ø6 MM from the ASSY MAGNETIC VALVE
6. Replace the ASSY MAGNETIC VALVE
19-3
19-2
19-1
19-5
19-4
19-6
Содержание i-team i-mop xxl
Страница 1: ...1 64 i mop xxl Service Manual Jan 2018 Warning read the instructions before using the machine...
Страница 10: ...10 64 7 Recovery tank 8 Left battery 9 Right battery 10 Transport wheels 11 Brush motors 9 7 8 10 11...
Страница 11: ...11 64 Internal view 1 Vacuum motor filter 2 Transparent plastic deflector 3 Vacuum hose 2 3 1...
Страница 53: ...53 65 2 14 Fasten 3pcs EJOT SCREW 50X14 to fix the COVER BRUSH MOTOR SCREW each side 53 1...
Страница 57: ...CHAPTER 16 ELECTRICAL SCHEME 57 65 57 1...
Страница 61: ...D if the reading is above 16V the battery is OK 61 65 61 1 61 2...
Страница 63: ...CHAPTER 19 REPAIR FLOW CHART 63 64 64 1 64 2...
Страница 64: ...64 64 65 1 Tennant Company PO Box 1452 Minneapolis MN 55440 Phone 1 800 553 8033 www tennantco com...