EN
ENGLISH
14
750 (08–02)
ELEVATED DRAINING
Use the convenient pump–out procedure if the drain
site exceeds 33 cm. in height.
1.
Attach the gray blower hose to the blower hose
connector and to the vacuum hose connector
(Figure 28).
FIG. 28
ATTENTION: Make sure recovery tank lid is secure
before activating blower.
2.
Remove the drain hose knob, direct the hose into
the elevated drain site and activate the blower
switch (Figure 29).
FIG. 29
EMPTYING SOLUTION TANK
1.
Connect the black recovery hose at the front of
the machine and remove the solution tank lid.
2.
Press the vacuum/blower switch towards the
vacuum symbol.
3.
Extract the remaining rinse solution from the
solution tank and flush out the tank with clean
water (Figure 30).
FIG. 30
4.
Turn off machine, unplug the power cord and the
drain recovery tank.
OTHER CLEANING USES WITH MACHINE
BLOWER HOSE CLEANING
Use the gray blower hose to blow out the debris from
hard to reach areas and to remove dust and cobwebs
from overhead fixtures and vents (Figure 31).
ATTENTION: Do not use machine for dry pick–up.
FIG. 31