Special Functions
This function resets the system to the zero position.
A reset may be required in the following cases:
• One of the components is removed
• The bases don’t work synchronously in tandem
operation
• After a power outage (only for tandem operation)
• System error
RESET PROCEDURE
Press and hold the
LEARN
button on the Control Box
for 3 seconds, until the red LED blinks. The LED will
blink three (3) times. Then press the
LEARN
button
five (5) times. The LED will blink quickly then remain
on. The process is complete.
The
Reset Procedure
clears the memory, so the
remote must now be learned. Refer to page 20
Programming Remotes
.
System Reset
Emergency Power‑Down
The two (2) 9-Volt batteries in the power supply give the
user the possibility to move the bed to a flat position
during power failure.
SINGLE SYSTEM
Press the
FLAT
button (5)
on the remote for 3
seconds and the bed will move to the flat position.
After this procedure the two (2) 9-Volt batteries must
be changed.
DANGER: Risk of pinching!
NOTE: During the emergency power-down
procedure the lowering speed may be reduced.
TANDEM OPERATION
STEP 1
Each base must be moved to the flat position
separately by following the Single System
Emergency Power-Down instructions.
STEP 2
After this procedure the two (2) 9-Volt batteries of
both power supplies must be changed.
NOTE: Do not mix old and new batteries.
CUSTOMER SERVICE: 1–800–821–6621