background image

®

Operation

Place Bracket Bolts (G) with a 5/16 inch washer (I) 
through the Outer Headboard Bracket (E) and into 
the Inner Headboard Bracket (D). Use 5/16 inch 
washers (I) and 5/16 inch nuts (J) and hand tighten to 
allow for adjustment.   

  

Repeat on the other side.

  STEP 1D 

Ensure the Headboard Bracket is assembled with a 
distance of 1.5 (38.1 mm) to 2 inches (50.8 mm) 
between the edge of the Ergo System and the 
headboard bracket assemblies. 

STEP 2 

Attach your headboard to the Headboard Brackets 
following the steps below:

  STEP 2A 

Measure the center-to-center distance of the 
mounting holes in your headboard.

  STEP 2B 

Measure the center-to-center distance of the 
mounting holes in the Headboard Bracket Assemblies.

  STEP 2C 

If the Headboard Brackets require adjustment, loosen 
the bolts that are holding the Outer Headboard 
Brackets and move them so that the mounting holes 
on the Outer Headboard Bracket align with the 
mounting holes on your headboard. Reinstall the 
bolts on the Outer Headboard Bracket and firmly 
tighten.

  STEP 2D 

Place your headboard bolts through the mounting 
holes on both the Outer Headboard Bracket and your 
headboard. Firmly tighten.

STEP 3 

Place your Tempur-Pedic mattress on top of your Ergo 
System Base.

WARNING:  Verify the space between the 
headboard cross member and the top of the 
mattress is no more than 3 inches.

Your TEMPUR

®

 Advanced Ergo System

 installation is now 

complete. Refer to the Wireless Remote Control Guide 
on the following pages or the supplied Quick Reference 
Guide for additional usage instructions.

Wireless Remote Control Programming

ONE WIRELESS REMOTE CONTROL AND ONE ERGO SYSTEM

NOTE: Only replacement wireless remote 
controls require user programming. You can 
program up to two remotes per base.

STEP 1 

Place four AAA batteries into the Wireless Remote 
Control.

STEP 2 

Ensure the Ergo System base is plugged into a 
functioning outlet.

STEP 3 

Locate the Emergency Power Down Box under the 
Ergo System base and install two (2) new 9-volt 
batteries.

STEP 4 

Lightly press the learn button for three (3) seconds.

STEP 5 

When the Green LED light illuminates, the RF 
frequency code setting function will be activated. 
Note: The LED light is located on the side of the 
plastic housing and is only visible when lit. If a new 
signal is not received, it will reset itself to normal 
mode in 10 seconds.

STEP 6 

Press any button on the wireless remote control. The 
Green LED light will blink once it receives a remote 
signal. Note: the bed will not respond for 10 seconds 
during the remote learn process.

STEP 7 

When the Green LED light on the Emergency Power 
Down Box turns off, you have completed the learning 
process of the RF frequency code.

NOTE: The remote programming procedure  
may also be performed using the learn    
button on the PLC.

ONE WIRELESS REMOTE CONTROL AND TWO ERGO SYSTEMS

STEP 1 

On your first Ergo System, follow the directions for one  
(1) wireless remote control and one (1) Ergo System.

STEP 2 

Once you have completed the programming of your first 
Ergo System, repeat the same directions for the second 
Ergo System using the same wireless remote control.

14

Customer Service: 1–800–979–1457 

15

Customer Service: 1–800–979–1457 

Содержание Double

Страница 1: ...COMPLETE REFERENCE GUIDE 2009 Tempur Pedic Management Inc 1713 Jaggie Fox Way Lexington KY 40511 All Rights Reserved U S Patent No 7 321 811 and other patents pending TPNA CRG TAES 0509 ...

Страница 2: ...ures outlined in the Complete Reference Guide this warranty and any other applicable document published or approved by Tempur Pedic d to damage to mattresses fabric cables electrical cords or items supplied by Resellers Contact the Reseller or relevant party for warranty information on these items e if there has been any unnecessary service calls including costs for in home service calls solely fo...

Страница 3: ... Check with a qualified electrician or serviceman if you are In doubt as to whether the product is properly grounded Do not modify the plug provided with the product if it will not fit the outlet have a proper outlet installed by a qualified electrician SAVE THESE INSTRUCTIONS GROUNDING SAFETY This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug i...

Страница 4: ...S WARNING After your Ergo System has been unboxed immediately dispose of packaging as it can smother small children and pets To avoid injury children and pets should not be allowed to play on or under the bed Children should not operate this product without adult supervision Close supervision is necessary when this furnishing is used by or near children invalids or disabled persons SAVE THESE INST...

Страница 5: ...f the assembled bed to be sure the Ergo System will fit One of our riser leg sets may be required in some cases WILL THE ERGO SYSTEM FIT INSIDE EXISTING FURNITURE The Ergo System is designed to fit into most freestanding beds We always recommend you measure the inside dimensions of the assembled bed to be sure the Ergo System will fit Please refer to the specifications on page 9 for exact dimensio...

Страница 6: ...ection into the pre threaded holes in the frame NOTE Hand tighten the legs securely to the frame Do NOT over tighten Make sure the legs are screwed completely into the frame Legs that are not securely attached may become unsafe DO NOT unscrew a leg to compensate for an uneven floor NOTE Your Ergo System is equipped with special locking casters In order to prevent the movement of this product all s...

Страница 7: ...base begins to move STEP 9 Detach the Mattress Retainer Bar B For shipping purposes the Mattress Retainer Bar comes installed upside down Using the Allen Wrench K loosen the Retainer Bar Bolts F and NOTE This step is only needed if using a headboard ONLY Not headboard footboard and side rails NOTE Failure to follow the proper headboard bracket installation instructions may result in damage to your...

Страница 8: ...Quick Reference Guide for additional usage instructions Wireless Remote Control Programming ONE WIRELESS REMOTE CONTROL AND ONE ERGO SYSTEM NOTE Only replacement wireless remote controls require user programming You can program up to two remotes per base STEP 1 Place four AAA batteries into the Wireless Remote Control STEP 2 Ensure the Ergo System base is plugged into a functioning outlet STEP 3 L...

Страница 9: ... button until the red LED Signature Light illuminates to activate the desired function This feature was installed to prevent any undesired movement should the wireless remote control be dropped etc C RETURN ALL SECTIONS TO THE FLAT POSITION E INCREASE REDUCE MASSAGE INTENSITY ON HEAD SECTION OF THE BASE G STOP ALL MASSAGE FEATURES B RAISE LOWER FOOT SECTION OF THE BASE D PROGRAM UP TO 4 MEMORY POS...

Страница 10: ...Êi iÊ vÊ the mattress Verify that a 1 5 38 1mm to 2 50 8mm distance is between the headboard brackets and the mattress Adjust if required SYMPTOM SOLUTION Head or Foot lift function has minor interference during operation UÊ iV ÊL ÌÌiÀ iÃÊ Ê7 Ài iÃÃÊ i ÌiÊ ÌÀ ÊÀi ViÊ with four 4 new AAA batteries if necessary UÊ iÊÃÕÀiÊÌ ÌÊÞ ÕÊ ÀiÊv Ü ÊÌ iÊ ÕÌÞÊVÞV iÊ of the motors do not operate more than two 2 m...

Страница 11: ...lights up on the Emergency Power Down Box STEP 3 Continue to press the Red Button until the base fully lowers to the flat position Ensure hands and arms are not in the path of moving parts NOTE Lowering using this method is much slower than the standard process FOR TECHNICAL SUPPORT OR SERVICE PLEASE CHOOSE FROM THE FOLLOWING NUMBERS QUESTIONS ABOUT YOUR ERGO SYSTEM BASE 1 800 979 1457 QUESTIONS A...

Отзывы: