Table 5 – Air Delivery
−
CFM (With Filter)*
FURNACE
SIZE
RETURN-AIR
INLET
SPEED
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0451412
Bottom or
Side(s)
High
Med-High
Medium
Med-Low
Low
1465
1295
1150
1030
860
1400
1260
1120
1010
835
1325
1210
1085
980
810
1250
1155
1040
945
780
1175
1090
985
895
745
1085
1015
920
835
700
980
930
835
765
635
860
830
740
685
555
725
700
620
570
445
560
545
510
345
260
0701412
Bottom or
Side(s)
High
Med-High
Medium
Med-Low
Low
1440
1180
1015
885
695
1400
1165
1020
885
700
1355
1150
1010
880
700
1300
1125
990
865
690
1240
1085
965
845
670
1170
1030
925
815
640
1090
970
875
770
600
1000
890
800
700
540
890
785
700
605
460
745
645
560
475
345
0901714
Bottom or
Side(s)
High
Med-High
Med-Low
Low
1650
1515
1385
1205
1600
1485
1360
1180
1535
1440
1320
1160
1465
1380
1260
1120
1385
1300
1195
1065
1285
1220
1120
1005
1175
1115
1025
925
1055
990
915
810
895
830
710
630
645
600
565
510
1102422
Bottom Only
High
Med-High
Medium
Med-Low
Low
2530
2225
1895
1565
1320
2460
2190
1885
1555
1295
2380
2135
1865
1535
1265
2285
2075
1820
1505
1235
2200
1995
1770
1465
1205
2085
1910
1700
1410
1160
1970
1805
1610
1350
1105
1835
1695
1520
1265
1035
1695
1565
1410
1175
950
1545
1430
1290
1050
870
Bottom Sides or
1 Side & Bottom
High
Med-High
--
2205
--
2175
2415
2120
2330
2065
2235
1975
2125
1900
1995
1790
1860
1685
1735
1580
1605
1460
1Side Only
High
Med-High
Medium
Med-Low
Low
2485
2155
1830
1520
1275
2430
2135
1830
1505
1260
2360
2100
1810
1490
1240
2270
2040
1780
1470
1210
2175
1970
1730
1430
1180
2070
1885
1665
1385
1135
1950
1790
1595
1330
1090
1825
1680
1505
1250
1025
1685
1560
1395
1165
930
1535
1420
1275
1055
840
*A filter is required for each return
−
air inlet. Airflow performance included 3/4
−
in. (19 mm) washable filter media such as contained in factory
−
authorized accessory filter
rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
−−
Indicates unstable operating conditions.
NOTE
: For horizontal applications, the top
−
most flange may
be bent past 90
to allow the evaporator coil to hang on the
flange temporarily while the remaining attachment and
sealing of the coil are performed.
Downflow Furnaces
Connect supply
−
air duct to supply
−
air outlet on furnace. Bend
flange inward past 90
with wide duct pliers. (See Figure 14)
The supply
−
air duct must be connected to ONLY the furnace
supply outlet or air conditioning coil casing (when used).
When installed on combustible material, supply
−
air duct must
be connected to ONLY the accessory combustible floor
subbase or a factory approved air conditioning coil casing.
DO NOT cut main furnace casing to attach supply side air
duct, humidifier, or other accessories. All accessories MUST
be connected to duct external to furnace casing.
Return Air Connections
FIRE HAZARD
Failure to follow this warning could cause personal
injury, death and/or property damage.
Never connect return
−
air ducts to the back of the
furnace. Follow instructions below.
!
WARNING
Downflow Furnaces
The return
−
air duct must be connected to return
−
air opening
(bottom inlet) as shown in Figure 1. DO NOT cut into casing
sides (left or right). Side opening is permitted for only upflow
and most horizontal furnaces. Bypass humidifier connections
should be made at ductwork or coil casing sides exterior to
furnace. (See Figure 19)
Upflow and Horizontal Furnaces
The return
−
air duct must be connected to bottom, sides (left
or right), or a combination of bottom and side(s) of main
furnace casing as shown in Figure 1. Bypass humidifier may
be attached into unused return air side of the furnace casing.
(See Figure 18 and Figure 20) Not all horizontal furnaces are
approved for side return air connections. (See Figure 20)
GAS PIPING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury,
death, and/or property damage.
Never purge a gas line into a combustion chamber.
Never test
for gas leaks with an open flame. Use a
commercially
available soap solution made
specifically for the detection of
leaks to check all
connections. A fire or explosion may result causing
property damage, personal injury or loss of life.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Use proper length of pipe to avoid stress on gas
control manifold and a gas leak.
!
WARNING