Figure 1
−
Dimensional Drawing
NOTES:
1. Two additional 7/8-in. (22 mm) diameter holes are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. (406 mm) round or 14 1/2 x 12-in. (368 x 305 mm) rectangle.
b. For 1200 CFM-20-in. (508 mm) round or 14 1/2 x 19 1/2-in. (368 x 495 mm) rectangle.
c. For 1600 CFM-22-in. (559 mm) round or 14 1/2 x 22 1/16-in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
Table 1 – Dimensions
FURNACE SIZE
A
B
C
D
VENT
SHIP
CABINET WIDTH
IN (mm)
OUTLET WIDTH
IN (mm)
TOP AND BOTTOM
FLUE COLLAR
IN (mm)
BOTTOM INLET
WIDTH
IN (mm)
VENT
CONNECTION
SIZE
IN (mm)
SHIP
WT
LB (KG)
0451412
14
−
3/16 (360)
12
−
9/16 (319)
9
−
5/16 (237)
12
−
11/16 (322)
4 (102)
107 (49)
0701412
14
−
3/16 (360)
12
−
9/16 (319)
9
−
5/16 (237)
12
−
11/16 (322)
4 (102)
115 (52)
0901714
17
−
1/2 (445)
15
−
7/8 (403)
11
−
9/16 (294)
16 (406)
4 (102)
127 (58)
1102122
21 (533)
19
−
3/8 (492)
13
−
5/16 (338)
19
−
1/2 (495)
4 (102)
152 (69)