Congratulations  on  your  purchase  of  high-quality  and  efficient  CALsys  1700  temperature  calibrator.Read  this 
manual  carefully  to  all  instructions  on  safety,  operation  and  maintenance.  It  serves  as  an  important  source  of 
information and reference for installation and operation of the device. The general safety requirements must be 
strictly adhered to when operating the device. The fact contained especially safety are observed. If you experience 
any further questions, please contact our technical support by phone or mail to

1.2

Liability and warranty

This instrument has been manufactured to exacting standards and is warranted for twelve months against electrical 
breakdown or mechanical failure caused through defective material or workmanship, provided the failure is not the 
result of misuse. In the event of failure covered by this warranty, the instrument must be returned, carriage paid, to 
the supplier for examination and will be replaced or repaired at our option.

INTERFERENCE  WITH  OR  FAILURE  TO  PROPERLY  MAINTAIN  THIS  INSTRUMENT  MAY  INVALID  THIS 
WARRANTY. 

1.3

Unpacking & Initial Inspection

Our packing department uses custom designed packaging to send out your unit, but as accidents can still happen in 
transit, you are advised, after unpacking the unit, to inspect it for any sign of damage, and confirm that your delivery 
is in accordance with the packing note. If you find any damage or find any part missing during delivery notify us and 
the carrier immediately. If the unit is damaged you should keep the packing for possible insurance assessment.    

After unpacking you will find following items.

 

 Phone No. 

0294-3052959

[email protected],

2

1. General Instruction

Calsys 1700

Heaters 4 Nos 

   Software CD

 

Rs-232

B Type T/C

Ceramic Block for Dry Block 

Ceramic Cavity for Black Body

Содержание CALsys 1700

Страница 1: ...CALsys 1700 USER MANUAL Temperature Calibrator TEMPSENS INSTRUMENTS l PVT LTD U ll Thermal Cable Solutions ...

Страница 2: ...m 4 Overview 5 4 1 Introduction 4 2 Outline description 5 Operating Instruction 9 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 10 6 1 The Temperature Controller 6 2 Altering the set point 6 3 Monitoring the Controlling Status 6 4 Units 7 Maintenance Trouble shooting 11 7 1 Maintenance 7 2 Troubleshooting 8 Software Installation 12 8 1 Installation 8 2 P...

Страница 3: ...is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier for examination and will be replaced or repaired at our option INTERFERENCE WITH OR FAILURE TO PROPERLY MAINTAIN THIS INSTRUMENT MAY INVALID THIS WARRANTY 1 3 Unpacking Initial Inspection Our packing department uses custom designed packaging to send out your un...

Страница 4: ... parts of the apparatus to prevent fire risk Ÿ Before connecting to the electricity supply please familiarize yourself with the parts of the calibrator with the help of operating manual Ÿ Burn Hazard Do not touch the target surface of the unit Ÿ Always replace the fuse with one of the same rating voltage and type Ÿ Overhead clearance is required Do not place unit under a cabinet or other structure...

Страница 5: ...ature Protection Autonics safety controller with BTypeT C Stabilization Time 15 to 20 Min Dimensions 640 H x 500 W x 550 D mm Block CavityAperture 2X6 5 2x8 5 mm with 140mm depth Ceremic 29MM dia end closed tube Weight Approx 80 kg 4 3 Technical Data 3 2 Circuit Diagram N P E R F Fan 230V AC Transformer Heater B Type T C P PHASE RED WIRE N NEUTRAL BLACK WIRE E EARTH BLUE WIRE N P MCB ROCKER SWITCH...

Страница 6: ...ainted by a high emissive paint The target is heated by MoSiO2 heaters which allows the source to heat up to 1700 C in about 3Hrs and hold it stable at temperature within 2 0 C The heater blockhouses consists a heater the controller sensor The temperature controller to sense the block temperature uses this sensor To obtain the maintain a required temperature the controller varies the power to the ...

Страница 7: ...ler to the PC I tools Download from Eurotherm website software is used for communicate the controller to PC and CALsoft for graphical view and data logging of the CALsys 1700 8 Controlling Sensor Connection Connect thermocouple wire to the controller terminal according to polarity There is difference between main controller and safety controller reading is not configured by others Main Controller ...

Страница 8: ...re force on h e a t e r a n d o t h e r element but connection should not be loosed 5 Insertion of heating element in ceremic board Measure the height should be around 40mm from insulation board Insertion of heating element 40 mm height after inserting heating element After insertion of heaters Note Heaters are very fragile so please assemble very very carefully and do not apply more force on h e ...

Страница 9: ...rom front side and after this all four nut bolt tight shown as below fix the ss chamber into outer cabinate nut bolt tight 12 After this the transformer lead connect through nut and bolt with the help of spanner in the open strip from back side as per shown in Figure cable connect with right open strip in back side cable connect with left open strip in back side 13 Screw tight the cable with the s...

Страница 10: ...tion Ÿ After the completely installation Ÿ Connect the CALsys 1700 to a suitable power supply ON the Mains switch located at back side with power entry Ÿ Set the desire temperature value in PID by using UP Down key Ÿ Aim the reference Master standard infrared temperature sensor to the target area Ÿ PV Present value display in controller will gradually rise until it reaches the set point temperatur...

Страница 11: ...es to indicate the new set point 6 3 Monitoring the Controller Status Arow indicate the controllers status as follows OP1 Heat Output REMThis beacon indicates activity on the PC interface ALM this indicates when PV Present value is more than 1700 C 6 4 Units Momentary pressing of the Scroll key will show the controller units C or F by using SCROLLkey UP DOWN key unit can be change IMPORTANT NOTICE...

Страница 12: ...ded Cleaning may be accomplished by the use of a small dry paint brush 7 2 Trouble Shooting 1 Unit Fails to Operate Check fuse if it is tripped switch is ON If not power ON of calsys 1700 consult us 2 Unit Unstable Controller parameter has been interfered consult us 3 If the temperature of the calibrator is not rising a The heating element may be open b The thermocouple may be open c TheThyristor ...

Страница 13: ...8 2 Parameter in Main Screen 8 2 1 Communication Communication between the furnace and the software is implemented via a RS 232 cable connected between the furnace and the PC serial port This enables the acquisition and recording of data as well as the transfer of commands from the software application to the tempsens furnace Communication can be done by clicking on connect and select correct COM ...

Страница 14: ...logging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVI Value Read the current PVvalue present value of furnace temperature File will be stored in xls formatto save previous recordopen the file by clicking on menu file open ...

Страница 15: ...eas or shipment overseas the device should be placed in welded foil ideally along with silicon gel to protect it from humidity Warranty TEMPSENS CALsys 1700 instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are not covered under this warranty Limit of Liability TEMPSENS not liable for any damages that arise from the use of a...

Страница 16: ...nd Instrumentation in various insulations as PTFE FEP PFA Kapton Silicon Fiber Glass Ceramic Fiber Refrasil Nextel PVCetc invarietyofconfigurations Thesecablesareavailableintemperaturerange 60 Cto1200 C All our products are manufactured under strict ISO 9001 quality management system We also provide Calibration Certificateswithallcables Westockmosttypesofcableswhichenableusforfastdeliveryofgoods O...