7. Maintenance & Trouble shooting

7.1 Maintenance

The calibration instrument has been designed with the utmost care. Ease of operation and

simplicity   of   maintenance   have   been   a   central   theme   in   the   product   development.
Therefore, with proper care the instrument should require very little maintenance. Avoid
operating the instrument in an oily, wet, dirty, or dusty environment.

If the outside of the instrument becomes soiled, it may be wiped clean with a damp cloth 

and mild detergent. Do not use harsh chemicals on the surface which may damage the 
paint.

Avoid knocking or dropping the calibrator.

If the mains supply cord becomes damaged, replace it with a cord with the appropriate 

gauge wire for the current of the instrument. 

Depending on the environment in which it is used, periodic cleaning is recommended. 

Cleaning may be accomplished by the use of a small dry paint brush.

 

 

                               

7.2 Trouble shooting
1. Unit fails to operate

Check fuse  if it is tripped switch is ON. If not power ON of calsys 1200 bath consult us.

 2.

 

Unit unstable

 Controller parameter has been interfered, consult us. 

3. If the temperature of the calibrator is not rising 

(a)

The heating element may be open.  

(b)

The thermocouple may be open. 

(c)

The SSR may be damaged.

(d)

The controller may not be giving output

(e)

The ambient temperature inside the chamber is raised and safety controller switched
OFF the power

 

CAUTIONARY NOTE   

TEMPSENS PRODUCTS ARE INTENDED FOR USE BY TECHNICALLY TRAINED AND COMPETENT
PERSONNEL FAMILIAR WITH GOOD MEASUREMENT PRACTICES.

IT IS EXPECTED THAT PERSONNEL USING THIS EQUIPMENT WILL BE COMPETENT WITH THE
MANAGEMENT   OF   APPARATUS   WHICH   MAY   BE   POWERED   OR   UNDER   EXTREMES   OF
TEMPERATURE, AND ARE ABLE TO APPRECIATE THE HAZARDS WHICH MAY BE ASSOCIATED
WITH, AND THE PRECAUTIONS TO BE TAKEN WITH, SUCH EQUIPMENT.

Содержание CALsys 1200

Страница 1: ...CALsys 1200 CALsys 1200 Dry block Temperature Calibrator USER MANUAL TEMPSENS INSTRUMENT I PVT LTD UNIT II...

Страница 2: ...2 Circuit diagram 4 Overview 4 4 1 Introduction 4 2 Outline description 5 Operating Instruction 5 5 1 Power 5 2 Setting the temperature 5 3 Operating Instruction 6 Operation of Controller 6 6 1 The T...

Страница 3: ...ctive material or workmanship provided the failure is not the result of misuse In the event of failure covered by this warranty the instrument must be returned carriage paid to the supplier for examin...

Страница 4: ...for repair Do not use the apparatus outside its recommended range i e 250 to 1200 C Ensure inflammable materials are kept away from hot parts of the apparatus to prevent fire risk Before connecting to...

Страница 5: ...ge 250 to 1200 C Resolution 0 1 C Stability 0 5 C Controlling sensor R type T C Time to reach max Temperature 90 Min Operating Temperature 20 to 45 C Controller Specifications Eurotherm Stabilization...

Страница 6: ...The CALsys models are part of wide range of portable calibrators designed and made by us Please contact us in case you required more information about our other products 4 2 Outline Description The c...

Страница 7: ...ze the temperature bath within 0 5 C of the set point 5 3 Operating Instruction 1 Insert the inconel block into well of furnace 2 Connect the CALsys 1200 to a suitable power supply Switch ON the Dry b...

Страница 8: ...point to the required value The lower display changes to indicate the new set point 6 3 Monitoring the Controller Status A row indicate the controllers status as follows OP1 Heat Output OP2 Cool Outpu...

Страница 9: ...recommended Cleaning may be accomplished by the use of a small dry paint brush 7 2 Trouble shooting 1 Unit fails to operate Check fuse if it is tripped switch is ON If not power ON of calsys 1200 bat...

Страница 10: ...f software 1 2 Parameter in mainscreen 1 2 1 Communication Communication between the furnace and the software is implemented via a RS 232 cable connected between the furnace and the PC serial port Thi...

Страница 11: ...ging up to 120 minutes than clickon start graph button After complete the task clickon save to file button Set Point C in which you can set temperature of furnace as your requirement PVI Value Read th...

Страница 12: ...th silicon gel to protect it from humidity Warranty TEMPSENS CALsys 1200 instrument have a warranty of one year from the invoice date This warranty covers manufacturing defects User induced faults are...

Страница 13: ...TEMPSENS INSTRUMENT I PVT LTD...

Отзывы: